To report the clinical utility of high-resolution ultrasound (US) for monitoring vascular compromise after free tissue transfer.
Fifty-two tissue transfers in the extremities were included in this study. Blood flow around the anastomotic pedicle and subcutaneous tissue of the grafted flap was monitored with pulsed color and power Doppler US whenever the conventional monitoring method, comprising the bedside assessment of the temperature, capillary refill, and flap color, showed abnormalities until 1 week after reconstruction.
All flaps were indicated for US monitoring, with 44 flaps showing Doppler signals in each position, even though conventional flap monitoring showed an abnormality. Forty of the 44 flaps showed no flap failure, whereas the remaining 4 flaps developed partial necrosis. Abnormal US findings were noted in 8 of the 52 flaps. Ultrasound revealed interruption of venous blood flow around the anastomotic pedicle in 6 of 8 flaps. Emergent exploration revealed venous occlusion at the anastomotic pedicle, similar to the US finding. In 2 of the 8 flaps, US showed no blood flow to either the anastomotic pedicle or subcutaneous tissue. Emergent exploration revealed arterial occlusion at the anastomotic pedicle. Seven of the 8 reexplored flaps were salvaged after revision surgery with complete flap survival. Partial flap survival was noted in 1 case, but complete flap failure was avoided.
Ultrasound is a useful adjunct that enables a direct assessment of perfusion in grafted tissues, which may reduce unnecessary exploration when conventional flap monitoring shows an abnormality.
报告高频超声(US)在监测游离组织移植后血管受压情况的临床应用价值。
本研究纳入了 52 例四肢组织转移患者。在常规监测方法(包括床边评估温度、毛细血管再充盈和皮瓣颜色)显示异常时,我们使用脉冲彩色和功率多普勒 US 监测吻合蒂周围和移植皮瓣的皮下组织血流,直至重建后 1 周。
所有皮瓣均行 US 监测,44 个皮瓣在每个位置均显示多普勒信号,尽管常规皮瓣监测显示异常。40 个皮瓣未发生皮瓣坏死,而其余 4 个皮瓣发生部分坏死。52 个皮瓣中有 8 个出现异常 US 发现。US 显示 6 个皮瓣吻合蒂周围静脉血流中断。紧急探查发现吻合蒂处静脉阻塞,与 US 发现一致。在 8 个皮瓣中的 2 个,US 显示吻合蒂或皮下组织均无血流。紧急探查发现吻合蒂处动脉阻塞。7 个再次探查的皮瓣经修正手术后得以挽救,皮瓣完全存活。1 例皮瓣部分存活,但避免了完全皮瓣坏死。
超声是一种有用的辅助手段,可直接评估移植组织的灌注情况,当常规皮瓣监测显示异常时,可减少不必要的探查。