Suppr超能文献

多次诊室血压测量:一种克服儿童血压测量薄弱基石的新方法。来自SPA项目的数据。

Multiple office blood pressure measurement: a novel approach to overcome the weak cornerstone of blood pressure measurement in children. Data from the SPA project.

作者信息

Ardissino Gianluigi, Ghiglia Silvia, Salice Patrizia, Perrone Michela, Piantanida Sandra, De Luca Francesco L, Di Michele Silvia, Filippucci Lucia, Dardi Elena R A, Bollani Tiziana, Mezzopane Antonella, Tchane Bertrand, Lava Sebastiano A G

机构信息

Pediatric Nephrology, Dialysis and Transplantation Unit - Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Pediatric Cardiology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

出版信息

Pediatr Nephrol. 2020 Apr;35(4):687-693. doi: 10.1007/s00467-019-04368-7. Epub 2020 Jan 3.

Abstract

BACKGROUND

This contribution aims to report and analyze a novel approach for office blood pressure measurement in children.

METHODS

Healthy children 5 to 8 years of age were eligible. After 5 minutes rest, 10 unattended blood pressure readings were taken at 3-minute intervals using a validated automated oscillometric device. After discarding outlier values (< 5th or > 95th percentile of the recorded values), the coefficient of variation and the mean of the 10 readings were calculated. The single readings #1 to #10 were compared with this elaborated average of the 10 measurements.

RESULTS

Two hundred eighty-one healthy, non-obese children (137 females, 49%), median age 5.7 (IQR 5.3-6.1) years, were analyzed. The median coefficients of variation were 7% (IQR 5-9) for systolic and 4% (IQR 3-6) for diastolic blood pressure. The first 3 measurements were significantly different from the average, while the readings #4 to #10 were not. Based on the average, only nine subjects had a systolic or diastolic blood pressure > 90th centile (n = 3 > 95th percentile).

CONCLUSIONS

Although most guidelines advise three blood pressure readings, these findings suggest that in children, office blood pressure measurement might be improved by including ten measurements. In situations of time constraints, the fourth blood pressure reading might be used as a reliable approximation.

摘要

背景

本研究旨在报告并分析一种用于儿童诊室血压测量的新方法。

方法

纳入5至8岁的健康儿童。休息5分钟后,使用经过验证的自动示波装置每隔3分钟进行10次无人值守的血压读数测量。剔除异常值(<记录值的第5百分位数或>第95百分位数)后,计算10次读数的变异系数和平均值。将单次读数#1至#10与这10次测量的详细平均值进行比较。

结果

对281名健康、非肥胖儿童(137名女性,49%)进行了分析,中位年龄5.7(IQR 5.3 - 6.1)岁。收缩压的中位变异系数为7%(IQR 5 - 9),舒张压为4%(IQR 3 - 6)。前3次测量与平均值有显著差异,而读数#4至#10则无差异。基于平均值,只有9名受试者的收缩压或舒张压>第90百分位数(n = 3 >第95百分位数)。

结论

尽管大多数指南建议测量三次血压,但这些结果表明,在儿童中,通过进行十次测量可能会改善诊室血压测量。在时间有限的情况下,第四次血压读数可作为可靠的近似值。