牙科设备水线中医院内细菌污染的评估:冲洗的影响。

Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing.

作者信息

Alkhulaifi Manal M, Alotaibi Dalal H, Alajlan Hisham, Binshoail Thekra

机构信息

Department of Botany and Microbiology, College of Science, King Saud University, Riyadh, Saudi Arabia.

Dental College, King Saud University, Riyadh, Saudi Arabia.

出版信息

Saudi Dent J. 2020 Feb;32(2):68-73. doi: 10.1016/j.sdentj.2019.07.003. Epub 2019 Jul 19.

Abstract

PURPOSE

This study evaluated the extent of bacterial contamination in water from dental unit waterlines (DUWLs).

METHODOLOGY

Water samples were collected (before flushing, 1 min post-flushing, and 3 min post-flushing) from 24 clinics (Group A: no disinfection, Group B: citric acid disinfectant) of a Government Dental College. Bacterial counts, identification, antibiotic sensitivity tests, determination of endotoxin levels, and scanning electron microscopy (to confirm the presence of biofilm) were performed.

RESULTS

The most common opportunistic bacteria were (95%), (58%), (49%), (44%), and (20%). Approximately 50% of the bacterial isolates were resistant to two or more antibiotics. Flushing for 3 min did not reduce the contamination of water from Group A clinics which exceeded the recommendation of ≤500 CFU/ml. No bacterial growth was seen in Group B samples. Endotoxin levels were >5.00 endotoxin units (EU)/ml in Group A and ranged from 1.33 to 5.00 EU/ml in Group B clinics. Scanning electron microscopy images showed bacterial biofilms on the surfaces of the tubes.

CONCLUSIONS

DUWL contamination is a serious issue in dentistry, and the microbiological quality of the water must be monitored regularly. Further studies on endotoxin exposure and prevention are therefore necessary.

摘要

目的

本研究评估了牙科设备水线(DUWLs)中水体的细菌污染程度。

方法

从一所政府牙科学院的24家诊所(A组:未进行消毒;B组:使用柠檬酸消毒剂)采集水样(冲洗前、冲洗后1分钟和冲洗后3分钟)。进行了细菌计数、鉴定、抗生素敏感性测试、内毒素水平测定以及扫描电子显微镜检查(以确认生物膜的存在)。

结果

最常见的机会致病菌为(95%)、(58%)、(49%)、(44%)和(20%)。约50%的细菌分离株对两种或更多种抗生素耐药。冲洗3分钟并未降低A组诊所超过≤500 CFU/ml推荐值的水体污染程度。B组样本未见细菌生长。A组内毒素水平>5.00内毒素单位(EU)/ml,B组诊所内毒素水平在1.33至5.00 EU/ml之间。扫描电子显微镜图像显示管表面存在细菌生物膜。

结论

DUWL污染是牙科领域的一个严重问题,必须定期监测水的微生物质量。因此,有必要对内毒素暴露和预防进行进一步研究。