用于选择气体交换数据来估计静息代谢率的方法对呼吸代谢仪提供的气体交换数据的影响。

Impact of the Method Used to Select Gas Exchange Data for Estimating the Resting Metabolic Rate, as Supplied by Breath-by-Breath Metabolic Carts.

机构信息

PROFITH "PROmoting FITness and Health Through Physical Activity" Research Group, Sport and Health University Research Institute (iMUDS), Department of Physical and Sports Education, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain.

Pennington Biomedical Research Center, Baton Rouge, LA 70808, USA.

出版信息

Nutrients. 2020 Feb 14;12(2):487. doi: 10.3390/nu12020487.

Abstract

The method used to select representative gas exchange data from large datasets influences the resting metabolic rate (RMR) returned. This study determines which of three methods yields the lowest RMR (as recommended for use in human energy balance studies), and in which method the greatest variance in RMR is explained by classical determinants of this variable. A total of 107 young and 74 middle-aged adults underwent a 30 min RMR examination using a breath-by-breath metabolic cart. Three gas exchange data selection methods were used: (i) steady state (SSt) for 3, 4, 5, or 10 min, (ii) a pre-defined time interval (TI), i.e., 6-10, 11-15, 16-20, 21-25, 26-30, 6-25, or 6-30 min, and (iii) "filtering", setting thresholds depending on the mean RMR value obtained. In both cohorts, the RMRs yielded by the SSt and filtering methods were significantly lower ( < 0.021) than those yielded by the TI method. No differences in RMR were seen under the different conditions of the SSt method, or of the filtering method. No differences were seen between the methods in terms of the variance in RMR explained by its classical determinants. In conclusion, the SSt and filtering methods return the lowest RMRs and intra-measurement coefficients of variation when using breath-by-breath metabolic carts.

摘要

从大型数据集选择有代表性的气体交换数据的方法会影响到测定的静息代谢率(RMR)。本研究旨在确定三种方法中的哪一种方法能得出最低的 RMR(推荐用于人类能量平衡研究),以及在这三种方法中,哪些因素可以最大程度地解释 RMR 的变化。共有 107 名年轻成年人和 74 名中年成年人接受了 30 分钟的呼吸代谢测试,采用逐口气的代谢箱进行检测。共使用了三种气体交换数据选择方法:(i)稳定状态(SSt)持续 3、4、5 或 10 分钟,(ii)预定义的时间间隔(TI),即 6-10、11-15、16-20、21-25、26-30、6-25 或 6-30 分钟,(iii)“过滤”,根据获得的平均 RMR 值设置阈值。在两个队列中,SSt 和过滤方法得到的 RMR 均显著低于(<0.021)TI 方法。SSt 方法的不同条件或过滤方法的不同条件下,RMR 没有差异。在 RMR 的经典决定因素解释的变异方面,三种方法没有差异。综上所述,使用呼吸代谢箱时,SSt 和过滤方法会得到最低的 RMR 和最小的测量内变异系数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/38c9/7071290/58bf1eb5b835/nutrients-12-00487-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验