Kadiroğulları Ersin, Timur Barış, Şen Onur, Kaya Mehmet
Department of Cardiovascular, University of Health Sciences, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, İstanbul, Turkey.
Turk Gogus Kalp Damar Cerrahisi Derg. 2018 Sep 16;26(4):642-645. doi: 10.5606/tgkdc.dergisi.2018.16361. eCollection 2018 Oct.
A 30-year-old male patient, who underwent Bentall De-Bono procedure due to type A aortic dissection six months ago presented to our clinic with acute lower extremity pain at rest. The warfarin dose was set to be between 2 and 3 of the international normalized ratio and the patient was discharged uneventfully after Bentall De-Bono operation. Computed tomography angiography revealed a thrombosis in the ascending aortic prosthetic graft, left iliac artery obstruction, and multiple infarcts in the spleen with an international normalized ratio of 2.2. The patient underwent reoperation and the isolated thrombus in the ascending aortic prosthetic graft was removed. Pathological examination of the material was compatible with a chronic thrombus.
一名30岁男性患者,6个月前因A型主动脉夹层接受了Bentall De-Bono手术,现因静息时急性下肢疼痛前来我院就诊。华法林剂量设定为国际标准化比值在2至3之间,该患者在Bentall De-Bono手术后顺利出院。计算机断层扫描血管造影显示升主动脉人工血管内血栓形成、左髂动脉阻塞以及脾脏多发梗死灶,国际标准化比值为2.2。患者接受了再次手术,切除了升主动脉人工血管内的孤立血栓。对该材料进行的病理检查结果与慢性血栓相符。