Suppr超能文献

使用CT淋巴管造影术和计算机辅助设计软件对特发性乳糜胸犬的乳糜池进行解剖学和容积特征分析。

Anatomic and volumetric characterization of the cisterna chyli using CT lymphangiography and computer-assisted design software in dogs with idiopathic chylothorax.

作者信息

Carvajal Jose L, Case J Brad, Vilaplana Grosso Federico, Huynh Elizabeth, Verpaalen Valentine, Fox-Alvarez Alexander, Regier Penny J

机构信息

Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida.

出版信息

Vet Radiol Ultrasound. 2020 May;61(3):312-321. doi: 10.1111/vru.12851. Epub 2020 Mar 3.

Abstract

The objectives of this retrospective, observational study were to characterize the anatomical features of the cisterna chyli (CC) in a cohort of dogs diagnosed with idiopathic chylothorax that underwent CT lymphangiography (CTLa), and to evaluate the feasibility of computer-assisted design (CAD) software to quantify volumetric measurements of the CC. Twenty-three client-owned dogs with idiopathic chylothorax were included. Additionally, CTLa was performed in three canine cadavers to assess the ability of CAD software to accurately acquire volumetric measurements. Injection sites, attenuation values, anatomic location, dimensions, and aortic diameter to CC ratio (Ao:CC) were recorded. Video records of video-assisted thoracic surgery (VATS) thoracic duct ligation (TDL) were reviewed in eight out of 23 dogs to compare operative and CTLa findings. The CC was dorsal and right-sided in 18 out of 23 dogs, located between L1 and L4 in 21 dogs, and extended as far cranially as T11 in two dogs. The median measurements for length, height, and width were 150.0, 5.5, and 13.3 mm, respectively. Median total volume was 1.82 mL. Median volumes to the right and left of the aorta were 1.46 and 0.49 mL, respectively (P = .014). Median total CC volume to body weight ratio (CC:bw) was 0.07 mL/kg. The presence of an intrathoracic CC was observed intraoperatively in six out of eight cases that underwent VATS TDL. Findings supported the use of CTLa and CAD as feasible methods for characterizing the CC in dogs diagnosed with chylothorax. These methods may facilitate interventional planning involving the CC such as embolization.

摘要

这项回顾性观察研究的目的是,在一组经CT淋巴管造影(CTLa)诊断为特发性乳糜胸的犬中,描述乳糜池(CC)的解剖特征,并评估计算机辅助设计(CAD)软件对CC进行容积测量的可行性。纳入了23只患特发性乳糜胸的家养犬。此外,对三只犬尸体进行了CTLa,以评估CAD软件准确获取容积测量值的能力。记录注射部位、衰减值、解剖位置、尺寸以及主动脉直径与CC的比值(Ao:CC)。对23只犬中的8只进行了电视辅助胸腔镜手术(VATS)胸导管结扎术(TDL)的视频记录回顾,以比较手术和CTLa的结果。23只犬中有18只的CC位于背侧且在右侧,21只位于L1和L4之间,两只犬的CC向上延伸至T11。长度、高度和宽度的中位数测量值分别为150.0、5.5和13.3毫米。总体积中位数为1.82毫升。主动脉右侧和左侧的体积中位数分别为1.46和0.49毫升(P = 0.014)。CC总体积与体重的中位数比值(CC:bw)为0.07毫升/千克。在接受VATS TDL的8例病例中,有6例术中观察到胸腔内有CC。研究结果支持将CTLa和CAD作为诊断乳糜胸犬CC特征的可行方法。这些方法可能有助于涉及CC的介入计划,如栓塞术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验