Suppr超能文献

手套对化学品的渗透:当前实践的最新技术 - 第 2 部分。重点研究高沸点化合物并模拟戴手套的环境。

Glove permeation of chemicals: The state of the art of current practice-Part 2. Research emphases on high boiling point compounds and simulating the donned glove environment.

机构信息

Program in Environmental Health, School of Community & Environmental Health, College of Health Sciences, Old Dominion University, Norfolk, Virginia.

Department of Environmental Health Sciences and UCLA Center for Occupational and Environmental Health, Fielding School of Public Health, University of California Los Angeles, Los Angeles, California.

出版信息

J Occup Environ Hyg. 2020 Apr;17(4):135-164. doi: 10.1080/15459624.2020.1721509. Epub 2020 Mar 25.

Abstract

This second part of the review of the 21 century literature on glove permeation is divided into the following major themes; permeation data and mathematical models, exposure/risk assessment, and manufacturer data. The major issues in the literature were the demonstrations that increasing temperature and applying forces increased permeation; and that glove manufacturer data were sometimes not reproducible. Double gloving of disposable gloves was found to be effective in resisting chemical permeation for short periods of time. Harmonization of standards and commercial glove classifications were called for at conditions that were closer to the temperature and applied forces actually present in the workplace, including whole glove testing and quantitative rather than just qualitative criteria. More research was recommended in each section and subsection with particular emphasis on defining the efficiency of solid phase collection devices, and more data in areas like exposure to cosmetics, household products, liquid foods, drinks, and cleaning liquids. More research in exposure assessment for permeated chemicals with sensors on the inner glove surface and on the skin was called for. Finally, it was decided that the state of the art of current practice was in a situation that needed the permeation standards, research, and the permeation charts of glove manufacturers to be at conditions that better reflected those encountered by workers with donned gloves.

摘要

这篇 21 世纪文献综述的第二部分分为以下几个主要主题:渗透数据和数学模型、暴露/风险评估和制造商数据。文献中的主要问题是,增加温度和施加力会增加渗透;而且手套制造商的数据有时不可重复。一次性手套的双层手套在短时间内有效地抵抗化学渗透。呼吁在更接近工作场所实际存在的温度和施加力的条件下,协调标准和商业手套分类,包括整个手套测试和定量而不仅仅是定性标准。在每个部分和子部分都建议进行更多的研究,特别强调定义固相收集装置的效率,并在接触化妆品、家用产品、液体食品、饮料和清洁液等领域增加更多的数据。呼吁在手套内表面和皮肤表面的传感器上对渗透到化学品进行更多的暴露评估研究。最后,人们决定,当前实践的技术水平需要渗透标准、研究和制造商的渗透图表在条件下更好地反映戴手套工人所遇到的情况。

相似文献

2
Glove permeation of chemicals: The state of the art of current practice, Part 1: Basics and the permeation standards.
J Occup Environ Hyg. 2019 Dec;16(12):827-839. doi: 10.1080/15459624.2019.1678754. Epub 2019 Nov 4.
3
Permeation of a firearm cleaning solvent through disposable nitrile gloves.
J Occup Environ Hyg. 2024 Jul;21(7):494-503. doi: 10.1080/15459624.2024.2345815. Epub 2024 Jun 5.
4
Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.
J Occup Environ Hyg. 2014;11(11):716-21. doi: 10.1080/15459624.2014.908259.
5
Fentanyl and carfentanil permeation through commercial disposable gloves.
J Occup Environ Hyg. 2020 Sep;17(9):398-407. doi: 10.1080/15459624.2020.1784426. Epub 2020 Jul 13.
6
Gloves and dermal exposure to chemicals: proposals for evaluating workplace effectiveness.
Ann Occup Hyg. 2004 Oct;48(7):607-15. doi: 10.1093/annhyg/meh060. Epub 2004 Sep 23.
7
8
Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison.
J Chem Health Saf. 2024 Mar 20;31(3):253-258. doi: 10.1021/acs.chas.3c00117. eCollection 2024 May 27.
9
A moving robotic hand system for whole-glove permeation and penetration: captan and nitrile gloves.
J Occup Environ Hyg. 2008 Apr;5(4):258-70. doi: 10.1080/15459620801934786.
10
Glove performance in a warming climate: The role of glove material and climate on permeation resistance to organophosphate insecticides.
J Occup Environ Hyg. 2021 Jan;18(1):4-15. doi: 10.1080/15459624.2020.1842879. Epub 2020 Nov 25.

引用本文的文献

1
Assessment of Occupational Exposure to Airborne Phenol and Biological Monitoring of Accumulation Trends.
Healthcare (Basel). 2025 Jun 25;13(13):1516. doi: 10.3390/healthcare13131516.
2
Permeation of a firearm cleaning solvent through disposable nitrile gloves.
J Occup Environ Hyg. 2024 Jul;21(7):494-503. doi: 10.1080/15459624.2024.2345815. Epub 2024 Jun 5.
3
Disposable Nitrile Glove Resistance to Limonene: Dextrous Robot Hand Versus ASTM F739 Comparison.
J Chem Health Saf. 2024 Mar 20;31(3):253-258. doi: 10.1021/acs.chas.3c00117. eCollection 2024 May 27.

本文引用的文献

1
Glove permeation of chemicals: The state of the art of current practice, Part 1: Basics and the permeation standards.
J Occup Environ Hyg. 2019 Dec;16(12):827-839. doi: 10.1080/15459624.2019.1678754. Epub 2019 Nov 4.
2
Testing of Disposable Protective Garments Against Isocyanate Permeation From Spray Polyurethane Foam Insulation.
Ann Work Expo Health. 2018 Jul 6;62(6):754-764. doi: 10.1093/annweh/wxy030.
3
Organophosphorus pesticide exposure in agriculture: effects of temperature, ultraviolet light and abrasion on PVC gloves.
Ind Health. 2018 Apr 7;56(2):166-170. doi: 10.2486/indhealth.2017-0157. Epub 2017 Dec 2.
4
Resistance of gloves and protective clothing materials to permeation of cytostatic solutions.
Int J Occup Med Environ Health. 2018 Jan 15;31(3):341-350. doi: 10.13075/ijomeh.1896.01140. Epub 2017 Nov 24.
7
Permeation of limonene through disposable nitrile gloves using a dextrous robot hand.
J Occup Health. 2017 Mar 28;59(2):131-138. doi: 10.1539/joh.16-0179-OA. Epub 2017 Jan 21.
10
Estimated exposure of hands inside the protective gloves used by non-occupational handlers of agricultural pesticides.
J Expo Sci Environ Epidemiol. 2017 Nov;27(6):625-631. doi: 10.1038/jes.2016.47. Epub 2016 Aug 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验