Suppr超能文献

对比增强光谱乳腺摄影与 MRI 在乳腺癌诊断中的荟萃分析。

A meta-analysis of contrast-enhanced spectral mammography versus MRI in the diagnosis of breast cancer.

机构信息

Department of Radiology, Lishui People's Hospital, Lishui, China.

Department of Clinical Laboratory, Lishui People's Hospital, Lishui, China.

出版信息

Thorac Cancer. 2020 Jun;11(6):1423-1432. doi: 10.1111/1759-7714.13400. Epub 2020 Mar 31.

Abstract

BACKGROUND

To identify the performance of contrast-enhanced spectral mammography (CESM) and magnetic resonance imaging (MRI) for breast cancer diagnosis by pooling the open published data.

METHODS

A systematic review of studies relevant to CESM and MRI in the diagnosis of breast cancer were screened in the electronic databases of Pubmed, EMBASE, the Cochrane Library, Web of Science, Google scholar and CNKI. The methodical quality of the included publications was evaluated by the quality assessment of diagnostic accuracy studies-2 (QUADAS-2). The diagnostic sensitivity, specificity and area under the ROC curve (AUC) were pooled and the true positive (TP), false positive (FP), false negative (FN) and true negative (TN) of the original studies were calculated.

RESULTS

A total of 13 diagnostic publications were identified and included in the meta-analysis. Of those included, five were retrospective studies and the remaining eight were prospective work. The combined data indicating the pooled sensitivity and specificity of CESM and MRI were 0.97 (95% CI: 0.95-0.98), 0.66 (95% CI: 0.59-0.71), 0.97 (95% CI: 0.95-0.98),and 0.52 (95% CI: 0.46-0.58), respectively. The pooled +LR and -LR for CESM were 2.70 (95% CI: 1.57-4.65), 0.06 (95% CI: 0.04-0.09), and 2.01 (95% CI: 1.78-2.26), 0.08 (95% CI: 0.05-0.11) for MRI, respectively. For the diagnostic odds ratio (DOR), the pooled results of CESM and MRI were 60.15 (95% CI: 24.72-146.37) and 31.34 (95% CI: 19.61-50.08), respectively. The AUC of the symmetric receiver operating characteristic curve (SROC) was 0.9794 and 0.9157 for CESM and MRI, respectively, calculated using the Moses model in the diagnosis of breast cancer.

CONCLUSIONS

Both CESM and MRI are effective methods for the detection of breast cancer with high diagnostic sensitivity. The diagnostic performance of CESM appears to be more effective than MRI.

摘要

背景

通过汇集公开发表的数据,确定对比增强光谱乳腺摄影术(CESM)和磁共振成像(MRI)在乳腺癌诊断中的性能。

方法

在 Pubmed、EMBASE、Cochrane 图书馆、Web of Science、Google scholar 和 CNKI 电子数据库中对与 CESM 和 MRI 在乳腺癌诊断相关的研究进行了系统筛选。使用诊断准确性研究质量评估-2(QUADAS-2)对纳入文献的方法学质量进行评估。汇总纳入研究的真阳性(TP)、假阳性(FP)、假阴性(FN)和真阴性(TN),计算原始研究的诊断敏感度、特异度和受试者工作特征曲线下面积(AUC)。

结果

共确定了 13 项诊断研究并纳入了荟萃分析。其中 5 项为回顾性研究,其余 8 项为前瞻性研究。CESM 和 MRI 的合并数据显示,其灵敏度和特异度分别为 0.97(95% CI:0.95-0.98)、0.66(95% CI:0.59-0.71)、0.97(95% CI:0.95-0.98)和 0.52(95% CI:0.46-0.58)。CESM 的阳性似然比(+LR)和阴性似然比(-LR)分别为 2.70(95% CI:1.57-4.65)、0.06(95% CI:0.04-0.09)和 2.01(95% CI:1.78-2.26)、0.08(95% CI:0.05-0.11)。对于诊断比值比(DOR),CESM 和 MRI 的合并结果分别为 60.15(95% CI:24.72-146.37)和 31.34(95% CI:19.61-50.08)。基于 Moses 模型,采用对称接收者操作特征曲线(SROC)计算的 CESM 和 MRI 诊断乳腺癌的 AUC 分别为 0.9794 和 0.9157。

结论

CESM 和 MRI 均为检测乳腺癌的有效方法,具有较高的诊断敏感度。CESM 的诊断性能似乎优于 MRI。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c716/7262891/83422410d5a9/TCA-11-1423-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验