Suppr超能文献

热循环后新型含MDP的释氟自粘树脂水门汀的微剪切粘结强度

Micro-Shear Bond Strength of Novel MDP Calcium-Fluoride-Releasing Self-Adhesive Resin Cement After Thermocycling.

作者信息

Mahrous Aliaa, Radwan Mohamed M, Kamel Samah Mohamed

出版信息

Int J Periodontics Restorative Dent. 2020 May/Jun;40(3):445-455. doi: 10.11607/prd.3992.

Abstract

The purpose of the present study was to (1) investigate the micro-shear bond strength and failure mode of a novel methacryloxydecyl-dihydrogen-phosphate (MDP) calcium-fluoride-releasing self-adhesive resin cement (TheraCem, BISCO) to a tooth structure (enamel and dentin) and to yttrium-stabilized zirconia after thermocycling, and to (2) compare the results with a universal non-MDP-containing self-adhesive resin cement (RelyX Unicem, 3M ESPE) as a control. Enamel and dentin specimens (20 discs each) were obtained by using a diamond saw (IsoMet 4000, Buehler) with copious water coolant. Twenty zirconia plates were obtained from IPS e.max ZirCAD blocks (Ivoclar Vivadent) and sintered in an inFire HTC speed high-temperature furnace (Dentsply Sirona). Resin-cement micro-cylinders were created on the bonded surface and filled with the tested cements (n = 10 for each surface/cement combination): Group A (control) used non-MDP-containing RelyX, whilegroup B (tested cement) used MDP-containing TheraCem MDP. Cements were left to self-cure for 5 minutes. All specimens were thermocycled for 5,000 cycles (THE-1100, SD Mechatronik). Micro-shear bond strength was measured using a universal testing machine, and debonded surfaces were examined for failure mode analysis with all morphologic and ultrastructure changes using a scanning electron microscope (Quanta 250 Field Emission Gun, FEI) attached with an energy dispersive x-ray (EDX) unit. The results were statistically analyzed. TheraCem had a slightly higher micro-shear bond strength (MPa) value than RelyX. Within enamel, TheraCem (6.46 ± 1.37 MPa) had a significantly higher mean μ-SBS value than RelyX (3.04 ± 0.99 MPa) ( = .002). Similarly, TheraCem in dentin (10.67 ± 1.27 MPa) had a significantly higher mean value than RelyX (6.46 ± 1.74 MPa) ( = .014). As for zirconia, TheraCem (39.76 ± 1.18 MPa) had a significantly higher mean μ-SBS value than RelyX (27.04 ± 1.92 MPa) ( < .001). Using MDP-containing calcium-fluoride-releasing self-adhesive resin cement (TheraCem) may improve bond strength to all tested substrates (enamel, dentin, and zirconia) and can be considered a promising cement for many clinicians. Further clinical studies are required to provide long-term clinical success data.

摘要

本研究的目的是

(1)研究一种新型的释放甲基丙烯酰氧基癸基磷酸二氢钙(MDP)的含氟钙自粘树脂水门汀(TheraCem,BISCO)在热循环后与牙体结构(釉质和牙本质)及钇稳定氧化锆的微剪切粘结强度和失效模式,以及(2)将结果与一种不含MDP的通用自粘树脂水门汀(RelyX Unicem,3M ESPE)作为对照进行比较。使用配备大量水冷装置的金刚石锯(IsoMet 4000,Buehler)获取釉质和牙本质标本(各20个圆盘)。从IPS e.max ZirCAD块体(Ivoclar Vivadent)获取20块氧化锆板,并在inFire HTC speed高温炉(Dentsply Sirona)中烧结。在粘结表面制作树脂水门汀微圆柱体,并填充测试水门汀(每种表面/水门汀组合n = 10):A组(对照组)使用不含MDP的RelyX,而B组(测试水门汀)使用含MDP的TheraCem MDP。水门汀自行固化5分钟。所有标本进行5000次热循环(THE - 1100,SD Mechatronik)。使用万能试验机测量微剪切粘结强度,并使用配备能量色散X射线(EDX)单元的扫描电子显微镜(Quanta 250场发射枪,FEI)检查脱粘表面的失效模式分析以及所有形态学和超微结构变化。对结果进行统计学分析。TheraCem的微剪切粘结强度(MPa)值略高于RelyX。在釉质中,TheraCem(6.46±1.37 MPa)的平均微剪切粘结强度值显著高于RelyX(3.04±0.99 MPa)(P = 0.002)。同样,在牙本质中,TheraCem(10.67±1.27 MPa)的平均值显著高于RelyX(6.46±1.74 MPa)(P = 0.014)。至于氧化锆,TheraCem(39.76±1.18 MPa)的平均微剪切粘结强度值显著高于RelyX(27.04±1.92 MPa)(P < 0.001)。使用含MDP的释放氟钙自粘树脂水门汀(TheraCem)可能会提高与所有测试基底(釉质、牙本质和氧化锆)的粘结强度,并且可被许多临床医生视为一种有前景的水门汀。需要进一步的临床研究以提供长期临床成功数据。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验