Suppr超能文献

瑞士口腔锥形束计算机断层摄影术的国家诊断参考水平的建立。

Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland.

机构信息

Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland.

Department of Radiology, University Hospital of Geneva, Geneva, Switzerland.

出版信息

Dentomaxillofac Radiol. 2020 Sep 1;49(6):20190468. doi: 10.1259/dmfr.20190468. Epub 2020 Apr 17.

Abstract

OBJECTIVES

The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland.

METHODS

A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P).

RESULTS

227 answers were collected (38% of all centers). Third quartile of P values were obtained for five dental indications: 662 mGy cm² for wisdom tooth, 683 mGy cm² for single tooth implant treatment, 542 mGy cm² for tooth position anomalies, 569 mGy cm² for pathological dentoalveolar modifications, and 639 mGy cm² for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed.

CONCLUSIONS

Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.

摘要

目的

本研究旨在使用瑞士口腔颌面和耳鼻喉科(ENT)锥形束 CT(CBCT)建立口腔颌面和耳鼻喉科领域的诊断参考水平(DRL)。

方法

向瑞士 CBCT 机所有者发送了一份问卷,共向 612 家机构发送了问卷。只要有足够的数据,就会对每个适应症进行分析。DRL 被定义为空气比释动能产物分布(P)的第 75 百分位数。

结果

共收集了 227 份答复(所有中心的 38%)。对于五个牙科适应症,获得了 P 值的第三四分位数:用于智齿的 662 mGy cm²,用于单牙种植治疗的 683 mGy cm²,用于牙齿位置异常的 542 mGy cm²,用于病理性牙牙槽骨改建的 569 mGy cm²,用于牙髓病的 639 mGy cm²。提出了标准视场(FOV)尺寸为 5 cm 直径 x 5 cm 高度。

结论

对于给定的适应症,FOV 和 P 的范围很大,这表明有必要制定 DRL 以及 FOV 建议,以优化目前的实践。由于 ENT 数据缺乏,本次调查无法从 ENT 实践中得出 ENT 实践的 DRL 值。