Management of postoperative cerebrospinal fluid (CSF) leaks is a challenge. Reexploration increases the morbidity risks. The main objective was to evaluate the outcomes of noninvasive zipper-like system (Zip surgical skin closure system, ZipLine Medical, Inc, Campbell, CA, USA) as a bailout technique for postoperative CSF leaks.
Retrospective case series. Consecutive patients with postoperative CSF leaks that occurred secondary to spinal surgeries performed between January 2017 and September 2018 were part of the study. All these patients were managed conservatively by reinforcement with zipper ratcheting straps over the sutured surgical wound. Successful clinical outcomes included cessation of CSF leaks and adequate wound healing in the postoperative period and at follow-up.
Ten patients underwent the application of zipper ratcheting straps. The mean follow-up was 6 months (range 6 months to 1 year). In 7 cases, the dural tears were recognized postoperatively and in 3 cases, the tears were noted intraoperatively and repaired and reinforced with fibrin sealants. None of the patients developed wound soakage or subsequent CSF leak from the wound after the application of zipper ratcheting straps.
Zipper ratcheting straps as augmentation to sewing of the wound seem to be a good alternative and bailout in treating patients with postoperative CSF leaks. The ease of its application, the ability in minimizing the complications associated with CSF leaks, and negating the need of surgical reexploration makes it a worthy option.
技术说明。
术后脑脊液漏的处理是一项挑战。再次手术会增加发病风险。主要目的是评估无创拉链式系统(Zip手术皮肤闭合系统,ZipLine Medical公司,美国加利福尼亚州坎贝尔)作为术后脑脊液漏的补救技术的效果。
回顾性病例系列研究。2017年1月至2018年9月期间因脊柱手术继发术后脑脊液漏的连续患者纳入本研究。所有这些患者均通过在缝合的手术伤口上使用拉链棘轮带进行加强保守治疗。成功的临床结果包括术后及随访期间脑脊液漏停止且伤口愈合良好。
10例患者应用了拉链棘轮带。平均随访时间为6个月(范围6个月至1年)。7例患者硬膜撕裂在术后被发现,3例患者的撕裂在术中被发现,经纤维蛋白密封剂修复并加强。应用拉链棘轮带后,所有患者均未出现伤口渗液或随后的伤口脑脊液漏。
拉链棘轮带作为伤口缝合的辅助手段,似乎是治疗术后脑脊液漏患者的一种良好替代方法和补救措施。其应用简便,能将与脑脊液漏相关的并发症降至最低,且无需再次手术探查,使其成为一个值得选择的方法。