Department of Civil Engineering, Shanghai University, 200444, China.
Shanghai Chengtou Wastewater Treatment Co., Ltd., Shanghai, 201203, China.
Chemosphere. 2020 Aug;252:126528. doi: 10.1016/j.chemosphere.2020.126528. Epub 2020 Mar 19.
The landfill sludge in storage reservoirs needs to be dewatered and disposed of for environmental and engineering purposes. The key factors are the high organic matter content and low permeability. Chemical conditioning is considered an efficient method for adjusting the properties of sludge. In this paper, two typical chemical agents, FeCl and a Fenton reagent with different additive amounts, are studied and compared for dewatering and consolidation purposes. Compression experiments and consolidation experiments are compared, and the coefficient of compressibility and compression index are obtained and compared. Then, the sludge permeability, grain size distribution variations, specific resistance to filtration (SRF) and morphology observations are considered to analyse the treatment mechanism. The results indicate that the properties of landfill sludge will change as the curing time increases. FeCl and Fenton are both effective in improving the consolidation and permeability properties of sludge. For the conditioning process, the optimum FeCl content is 20%, and the process is dominated by coagulation if FeCl is less than 20%; otherwise, it is dominated by hydrolysis. For the Fenton reagent, the optimum Fe content and HO content are 4% and 12%, respectively. The depolymerization effect of the Fenton reagent leads to the oxidation and recombination of the polar group on extracellular polymeric substances (EPSs). The results can be used to explain the conditioning mechanism of the effective agents of FeCl and Fenton and compare the corresponding consolidation properties. The consolidation characteristics provide a reference for further application of vacuum preloading in the sludge disposal process.
为了环境和工程目的,需要对储存库中的垃圾填埋场污泥进行脱水和处理。关键因素是有机物含量高和渗透性低。化学调理被认为是调节污泥性质的有效方法。本文研究并比较了两种典型的化学药剂,即不同添加量的 FeCl 和 Fenton 试剂,用于脱水和固结目的。比较了压缩实验和固结实验,得到并比较了压缩系数和压缩指数。然后,考虑了污泥渗透率、粒度分布变化、比过滤阻力 (SRF) 和形态观察,以分析处理机制。结果表明,随着养护时间的增加,垃圾填埋场污泥的性质会发生变化。FeCl 和 Fenton 都能有效改善污泥的固结和渗透性。对于调理过程,FeCl 的最佳含量为 20%,如果 FeCl 小于 20%,则以混凝为主;否则,以水解为主。对于 Fenton 试剂,最佳的 Fe 含量和 HO 含量分别为 4%和 12%。Fenton 试剂的解聚作用导致细胞外聚合物 (EPS) 上的极性基团氧化和重组。结果可以用来解释 FeCl 和 Fenton 有效药剂的调理机制,并比较相应的固结性能。固结特性为真空预压在污泥处理过程中的进一步应用提供了参考。