在明、暗两种条件下,通过 van Herick 分级和超声生物显微镜评估前房角,以发现房角关闭和房角平坦虹膜构型。

Evaluation of anterior chamber angle by van Herick grading and ultrasound biomicroscopy in light and dark conditions for finding appositional angle closure and plateau iris configuration.

机构信息

Department of Ophthalmology, Faculty of Medicine, University of Ryukyu, Naha, Okinawa, Japan.

Eye Institute, Cleveland Clinic, Abu Dhabi, United Arab Emirates.

出版信息

Acta Ophthalmol. 2021 Feb;99(1):e86-e95. doi: 10.1111/aos.14502. Epub 2020 Jun 22.

Abstract

PURPOSE

To evaluate association of the van Herick (VH) grades with the ultrasound biomicroscopic (UBM) parameters, appositional irido-trabecular contact (A-ITC) and plateau iris (PI) in a randomly sampled population.

METHODS

A 10% random sample of all residents aged 40 or older of the Kumejima study underwent UBM under dark and light conditions in the four quadrants of right eyes.

RESULTS

Of 301 right eyes with eligible UBM images, 101 (33.6%) and 200 (66.4%) were classified as VH ≤ 2 and VH ≥ 3, respectively. The UBM parameters on angle width and ciliary body configuration were significantly different between VH ≤ 2 and VH ≥ 3 eyes (p < 0.001). A-ITC was found in at least one quadrant in 54.5% and 75.2% of VH ≤ 2 eyes under light and dark conditions, respectively; and 20.5% and 45.5% of VH ≥ 3 eyes. When 'VH ≤ 2' was used to screen eyes with A-ITC in three or more quadrants, the sensitivity and specificity were 74.1% and 75.3%, respectively. A-ITC was significantly associated with shallower anterior chamber (p = 0.018) and higher intraocular pressure (p = 0.044) in VH ≥ 3 eyes. Plateau iris (PI) was found in 15.8% and 6.0% of VH ≤ 2 and VH ≥ 3 eyes, respectively. Plateau iris (PI) was significantly associated with the UBM parameters on angle width and ciliary body configuration. When 'VH ≤ 2' was used to screen eyes with PI, the sensitivity and specificity were 57.1% and 68.9%, respectively.

CONCLUSIONS

The VH grade of ≤2 and ≥3 showed significant association with UBM angle width and ciliary body configuration parameters. The VH ≤ 2 criterion should be useful for screening of A-ITC and PI.

摘要

目的

评估 Van Herick(VH)分级与超声生物显微镜(UBM)参数、房角虹膜贴附(A-ITC)和虹膜平坦在随机抽样人群中的相关性。

方法

对 Kumejima 研究中所有 40 岁或以上的居民进行 10%的随机抽样,在右眼的四个象限中在暗室和明室条件下进行 UBM。

结果

在 301 只可进行 UBM 检查的右眼图像中,101 只(33.6%)和 200 只(66.4%)分别归类为 VH≤2 和 VH≥3。在 VH≤2 和 VH≥3 眼中,UBM 角度宽度和睫状体形态参数有显著差异(p<0.001)。在明室和暗室条件下,VH≤2 眼中至少一个象限存在 A-ITC 的比例分别为 54.5%和 75.2%;VH≥3 眼中的比例分别为 20.5%和 45.5%。当“VH≤2”用于筛选三个或更多象限存在 A-ITC 的眼睛时,其敏感性和特异性分别为 74.1%和 75.3%。A-ITC 与较浅的前房深度(p=0.018)和较高的眼内压(p=0.044)显著相关。在 VH≥3 眼中,发现 15.8%和 6.0%的眼睛存在虹膜平坦(PI)。虹膜平坦(PI)与 UBM 角度宽度和睫状体形态参数显著相关。当“VH≤2”用于筛选存在 PI 的眼睛时,其敏感性和特异性分别为 57.1%和 68.9%。

结论

VH 分级≤2 和≥3 与 UBM 角度宽度和睫状体形态参数显著相关。VH≤2 标准可用于筛选 A-ITC 和 PI。