Containment strategies and clinical management of coronavirus disease (COVID-19) patients during the current pandemic depend on reliable diagnostic PCR assays for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Here, we compare 11 different RT-PCR test systems used in seven diagnostic laboratories in Germany in March 2020. While most assays performed well, we identified detection problems in a commonly used assay that may have resulted in false-negative test results during the first weeks of the pandemic.

摘要

在当前大流行期间,对冠状病毒病 (COVID-19) 患者的控制策略和临床管理取决于对严重急性呼吸综合征冠状病毒 2 (SARS-CoV-2) 的可靠诊断 PCR 检测。在这里,我们比较了 2020 年 3 月德国七个诊断实验室使用的 11 种不同的 RT-PCR 检测系统。虽然大多数检测方法都表现良好,但我们发现一种常用检测方法存在检测问题,这可能导致大流行的最初几周内出现假阴性检测结果。