Suppr超能文献

环介导等温扩增技术在儿童侵袭性脑膜炎球菌病早期诊断中的应用。

Loop-mediated isothermal amplification for the early diagnosis of invasive meningococcal disease in children.

机构信息

Wellcome-Wolfson Institute for Experimental Medicine, Queen's University Belfast, Belfast, UK

Emergency Department, Royal Belfast Children's Hospital, Belfast, UK.

出版信息

Arch Dis Child. 2020 Dec;105(12):1151-1156. doi: 10.1136/archdischild-2020-319139. Epub 2020 Jun 25.

Abstract

BACKGROUND

Rapid molecular diagnostic testing has the potential to improve the early recognition of meningococcal disease (MD). The aim of this study was to report on the diagnostic test accuracy of point-of-care loop-mediated isothermal amplification (LAMP) in the diagnosis of MD.

DESIGN

Data were collected prospectively from three UK emergency departments (ED) between November 2017 and June 2019. Consecutive children under 18 years of age attending the ED with features of MD were eligible for inclusion. The meningococcal LAMP test (index test) was performed on a dry swab of the child's oropharynx. Reference standard testing was the confirmation of invasive MD defined as positive culture or PCR result from a sterile body site (blood or cerebrospinal fluid).

RESULTS

There were 260 children included in the final analysis. The median age was 2 years 11 months and 169 (65%) children were aged 5 years or younger. The LAMP test was negative in 246 children and positive in 14 children. Of the 14 children with positive LAMP tests, there were five cases of invasive MD. Of the 246 children with negative LAMP tests, there were no cases of invasive MD. The sensitivity of LAMP testing was 1.00 and the specificity was 0.97. The negative and positive predictive values were 1.00 and 0.36, respectively. The positive likelihood ratio was 28.3.

DISCUSSION

Non-invasive LAMP testing using oropharyngeal swabs provided an accurate fast and minimally invasive mechanism for predicting invasive MD in this study.

TRIAL REGISTRATION NUMBER

NCT03378258.

摘要

背景

快速分子诊断测试有可能提高对脑膜炎球菌病(MD)的早期识别。本研究的目的是报告床边环介导等温扩增(LAMP)在 MD 诊断中的诊断测试准确性。

设计

数据是在 2017 年 11 月至 2019 年 6 月期间从英国的三个急诊部门(ED)前瞻性收集的。符合 MD 特征的 18 岁以下连续就诊于 ED 的儿童符合纳入标准。对儿童的干燥咽拭子进行脑膜炎球菌 LAMP 测试(指标测试)。参考标准测试是确认侵袭性 MD,定义为从无菌部位(血液或脑脊液)获得的阳性培养或 PCR 结果。

结果

最终分析共纳入 260 名儿童。中位年龄为 2 岁 11 个月,169 名(65%)儿童年龄在 5 岁或以下。246 名儿童的 LAMP 检测结果为阴性,14 名儿童的 LAMP 检测结果为阳性。在 14 名 LAMP 检测结果阳性的儿童中,有 5 例为侵袭性 MD。在 246 名 LAMP 检测结果阴性的儿童中,无侵袭性 MD 病例。LAMP 检测的敏感性为 1.00,特异性为 0.97。阴性和阳性预测值分别为 1.00 和 0.36,阳性似然比为 28.3。

讨论

本研究中,使用咽拭子的非侵入性 LAMP 测试为预测侵袭性 MD 提供了一种准确、快速且微创的机制。

临床试验注册号

NCT03378258。