LISiN - Laboratory for Engineering of the Neuromuscular System, Department of Electronics and Telecommunications - Politecnico di Torino, Turin, Italy.
LISiN - Laboratory for Engineering of the Neuromuscular System, Department of Electronics and Telecommunications - Politecnico di Torino, Turin, Italy.
J Electromyogr Kinesiol. 2020 Oct;54:102440. doi: 10.1016/j.jelekin.2020.102440. Epub 2020 Jun 26.
This tutorial is aimed primarily to non-engineers, using or planning to use surface electromyography (sEMG) as an assessment tool for muscle evaluation in the prevention, monitoring, assessment and rehabilitation fields. The main purpose is to explain basic concepts related to: (a) signal detection (electrodes, electrode-skin interface, noise, ECG and power line interference), (b) basic signal properties, such as amplitude and bandwidth, (c) parameters of the front-end amplifier (input impedance, noise, CMRR, bandwidth, etc.), (d) techniques for interference and artifact reduction, (e) signal filtering, (f) sampling and (g) A/D conversion, These concepts are addressed and discussed, with examples. The second purpose is to outline best practices and provide general guidelines for proper signal detection, conditioning and A/D conversion, aimed to clinical operators and biomedical engineers. Issues related to the sEMG origin and to electrode size, interelectrode distance and location, have been discussed in a previous tutorial. Issues related to signal processing for information extraction will be discussed in a subsequent tutorial.
本教程主要针对非工程师,他们使用或计划使用表面肌电图 (sEMG) 作为预防、监测、评估和康复领域的肌肉评估工具。主要目的是解释与以下方面相关的基本概念:(a) 信号检测(电极、电极-皮肤界面、噪声、心电图和电源线干扰),(b) 基本信号特性,如幅度和带宽,(c) 前端放大器的参数(输入阻抗、噪声、CMRR、带宽等),(d) 干扰和伪影减少技术,(e) 信号滤波,(f) 采样和 (g) A/D 转换,这些概念将通过示例进行介绍和讨论。第二个目的是为临床操作人员和生物医学工程师概述适当的信号检测、调理和 A/D 转换的最佳实践和一般准则。与 sEMG 起源以及电极尺寸、电极间距离和位置相关的问题已在之前的教程中进行了讨论。与信息提取的信号处理相关的问题将在后续教程中进行讨论。