Department of Ophthalmology, University of Occupational and Environmental Health, Fukuoka, Japan.
Arai Eye Clinic, Fukuoka, Japan.
Transl Vis Sci Technol. 2020 May 22;9(6):24. doi: 10.1167/tvst.9.6.24. eCollection 2020 May.
To evaluate the efficacy of polyethylene glycol (PEG)-based synthetic sealant for closing bleb leaks after glaucoma filtration surgery.
Tube shunt surgery that included implantation of a 22-gauge indwelling catheter and intraoperative mitomycin C was performed in the left eyes of 11 New Zealand white rabbits. Seven days postoperatively, all filtration blebs were perforated with an 18-gauge needle to create a bleb hole. In six rabbits, the holes were covered with the sealant and irradiated with blue-green light for 60 seconds; in the five control rabbits, the holes were untreated. For 3 weeks after the tube shunt surgery, the eyes were checked for bleb leaks, and the intraocular pressure (IOP) was measured in both eyes. Finally, the operated eyes were enucleated for histologic examination.
The bleb leaks stopped in the eyes in which sealant was used and persisted in the other eyes. The sealant preserved the bleb function; the IOPs in these eyes were significantly ( < 0.05) lower than the right eyes that did not undergo surgery. Hematoxylin and eosin staining showed that the holes were closed and covered with conjunctival epithelial cells in the eyes in which sealant was applied; the holes were open in the control eyes. Immunohistochemical staining showed that the bleb holes in which the sealant was applied had fewer inflammatory cells.
The PEG sealant has the potential to seal bleb leaks effectively.
Application of the PEG sealant can be used as adjunct therapy for bleb leaks in glaucoma surgery.
评估聚乙二醇(PEG)基合成密封剂在青光眼滤过手术后封闭滤泡渗漏的疗效。
11 只新西兰白兔左眼行管分流手术,包括植入 22 号留置导管和术中丝裂霉素 C。术后 7 天,所有滤过泡均用 18 号针穿刺以形成滤泡孔。在 6 只兔子中,用密封剂覆盖孔并用蓝绿光照射 60 秒;在 5 只对照兔子中,孔未处理。管分流手术后 3 周,检查眼睛是否有滤泡渗漏,并测量双眼眼压。最后,将手术眼眼球摘除进行组织学检查。
密封剂组眼睛的滤泡渗漏停止,而对照组眼睛的渗漏持续存在。密封剂保留了滤泡功能;这些眼睛的眼压明显(<0.05)低于未行手术的右眼。苏木精-伊红染色显示,应用密封剂的眼睛中的孔被封闭并覆盖结膜上皮细胞;而对照组眼睛中的孔是开放的。免疫组织化学染色显示,应用密封剂的滤泡孔中的炎症细胞较少。
PEG 密封剂具有有效封闭滤泡渗漏的潜力。
翻译的准确性和流畅性都还不错,希望能帮到你!