Suppr超能文献

Comparison of magnetic resonance imaging and radionuclide imaging in the evaluation of renal transplant failure.

作者信息

Goldsmith M S, Tanasescu D E, Waxman A D, Crues J V

机构信息

Department of Radiology, Cedars-Sinai Medical Center, Los Angeles, California 90048.

出版信息

Clin Nucl Med. 1988 Apr;13(4):250-7. doi: 10.1097/00003072-198804000-00005.

Abstract

Magnetic resonance imaging (MRI) was compared with radionuclide scintigraphy (RNS) in 16 patients with renal transplants undergoing renal failure to determine which modality could best discriminate between rejection, acute tubular necrosis (ATN), and cyclosporin nephrotoxicity (CN). Although all rejecting transplants had reduced corticomedullary differentiation (CMD) on T1-weighted MR images, four of five cases of ATN had appearances that could not be distinguished from rejection. A normal CMD suggests nonrejection, but diminished CMD is nonspecific. Tc-99m DTPA/I-131 hippuran RNS was superior to MRI in differentiating rejection from ATN. Although ATN and CN have similar RNS patterns, this distinction can usually be made based on the clinical time course. Other potential uses of MRI in the evaluation of the renal transplants are discussed.