Suppr超能文献

便携式呼气计检测儿童和青少年口臭的准确性。

Accuracy of a portable breath meter test for the detection of halitosis in children and adolescents.

作者信息

Guedes Carolina Cardoso, Bussadori Sandra Kalil, Garcia Ana Carolina Mota, Motta Lara Jansiski, Gomes Andréa Oliver, Weber Raimar, Amancio Olga Maria Silverio

机构信息

Departamento de Pediatria, Universidade Federal de Sao Paulo, Sao Paulo, SP, BR.

Universidade Nove de Julho, São Paulo, SP, BR.

出版信息

Clinics (Sao Paulo). 2020 Sep 11;75:e1764. doi: 10.6061/clinics/2020/e1764. eCollection 2020.

Abstract

OBJECTIVES

This study aimed to determine the accuracy of the Breath-Alert™ portable breath meter (BA) for the detection of halitosis in children and adolescents, considering the organoleptic test (OT) as the gold standard in this assessment.

METHODS

A cross-sectional study was conducted on 150 children (aged 6-12 years). OT was performed by three independent examiners on a single occasion, obtaining three scores of 0-5 points on the Rosenberg's organoleptic scale. The median of the three evaluations for each child was used for analysis. BA was used according to the manufacturer's instructions, with breath odor scored from 0-5 points. Scores ≥2 on both tests were considered indicative of halitosis.

RESULTS

A total of 26 (17.3%) and 23 (15.3%) children were detected with halitosis on the OT and BA tests, respectively. The sensitivity and specificity of the BA scores for the detection of halitosis were 80.76% and 98.38%, respectively. The positive and negative predictive values for BA were 91.3% and 96.06%, respectively.

CONCLUSION

In the present study involving children, who require fast, practical examinations, BA proved to be an auxiliary tool to OT for the detection of halitosis in the practice of pediatric dentistry, demonstrating high sensitivity and specificity.

摘要

目的

本研究旨在确定Breath-Alert™便携式呼吸检测仪(BA)检测儿童和青少年口臭的准确性,将感官测试(OT)作为该评估的金标准。

方法

对150名6至12岁儿童进行了一项横断面研究。由三名独立检查者一次性进行OT,在罗森伯格感官量表上获得三个0至5分的评分。每个儿童三次评估的中位数用于分析。BA按照制造商的说明使用,呼吸气味评分为0至5分。两项测试得分均≥2分被视为口臭。

结果

OT和BA测试分别检测出26名(17.3%)和23名(15.3%)儿童患有口臭。BA评分检测口臭的敏感性和特异性分别为80.76%和98.38%。BA的阳性和阴性预测值分别为91.3%和96.06%。

结论

在本涉及儿童的研究中,儿童需要快速、实用的检查,在儿童牙科实践中,BA被证明是OT检测口臭的辅助工具,具有较高的敏感性和特异性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b0dd/7470429/b8947933ac9a/cln-75-e1764-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验