Sports Medicine Institute, Hospital for Special Surgery, New York, New York, U.S.A.
Department of Orthopaedic Surgery, Loma Linda University Medical Center, Loma Linda, California, U.S.A.
Arthroscopy. 2021 Mar;37(3):953-960. doi: 10.1016/j.arthro.2020.10.040. Epub 2020 Oct 29.
To evaluate the effect of soaking of anterior cruciate ligament (ACL) grafts in vancomycin solution on graft biomechanical properties at the time of implantation.
The central third of patellar tendons was harvested from mature bovine knees and prepared as a tendon-only graft or a bone-tendon-bone (BTB) graft. Tendons were wrapped in gauze soaked in vancomycin solution (VS) (5 mg/mL) or normal saline (NS) and left to stand for 30 minutes at room temperature, simulating graft exposure times in the operating room during ACL reconstruction. Tensile testing was carried out on a materials testing system with (1) low-magnitude loading (60 N at 3 mm/s) with repeated testing of tendon-only grafts; and (2) high-magnitude loading (600 N at 10 mm/min) of BTB grafts. For tendon-only grafts, specimens were first wrapped in NS-soaked gauze and underwent testing, with repeated testing performed after wrapping in gauze soaked in VS or buffered VS (pH 7.0). For BTB grafts, specimens were randomly assigned to treatment with VS or NS.
For tendon-only grafts, there was no difference in Young's modulus (YM) after soaking with VS soaking (baseline, 12.69 MPa; treatment, 16.07 ± 4.44 MPa; P = .99) or buffered VS (baseline, 12.45 ± 4.55 MPa; treatment, 15.56 ± 2.83 MPa; P = .99). For BTB grafts, there were no differences in elongation strain (VS, 46.8% ± 7.0%; NS, 31.5% ± 13.5%, P = .19) or YM (VS, 158.4 ± 15.8 MPa; NS, 158.5 ± 23.3 MPa, P = .99).
According to controlled biomechanical tests, vancomycin soaking of patellar tendon grafts does not adversely affect time-zero material properties.
This study suggests that vancomycin wrapping has no immediate adverse effects on the biomechanical properties of ACL grafts. Randomized controlled trials are warranted to validate the widespread use of vancomycin soaking of tendon grafts for infection prophylaxis during ACL reconstruction.
评估在植入前将前交叉韧带(ACL)移植物浸泡在万古霉素溶液中对移植物生物力学性能的影响。
从成熟牛膝关节中采集髌腱的中央三分之一,制备成仅腱移植物或骨-腱-骨(BTB)移植物。将肌腱用浸泡在万古霉素溶液(VS)(5mg/ml)或生理盐水(NS)中的纱布包裹,并在室温下放置 30 分钟,模拟 ACL 重建过程中手术室中移植物的暴露时间。使用材料测试系统对肌腱仅移植物进行低幅度加载(60N,3mm/s),进行重复测试;对 BTB 移植物进行高幅度加载(600N,10mm/min)。对于仅腱移植物,首先将标本用 NS 浸泡的纱布包裹并进行测试,然后用 VS 或缓冲的 VS(pH7.0)浸泡的纱布包裹后进行重复测试。对于 BTB 移植物,将标本随机分配接受 VS 或 NS 处理。
对于仅腱移植物,VS 浸泡后杨氏模量(YM)无差异(基线,12.69MPa;处理,16.07±4.44MPa;P=0.99)或缓冲 VS(基线,12.45±4.55MPa;处理,15.56±2.83MPa;P=0.99)。对于 BTB 移植物,伸长应变(VS,46.8%±7.0%;NS,31.5%±13.5%,P=0.19)或 YM(VS,158.4±15.8MPa;NS,158.5±23.3MPa,P=0.99)无差异。
根据对照生物力学测试,万古霉素浸泡髌腱移植物不会对零时材料性能产生不利影响。
本研究表明,万古霉素包裹对 ACL 移植物的生物力学性能没有即时的不良影响。需要进行随机对照试验来验证万古霉素浸泡肌腱移植物在 ACL 重建中预防感染的广泛应用。