Suppr超能文献

Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT.

作者信息

El-Fayoumi Dina, Bahgat Nermeen, Khafagy Mohamed, Hatata Ragai, Sabry Dalia, Allam Ghada, Kasem Manal Ali, Sadek Sherin

机构信息

Ophthalmology Department, Faculty of Medicine, Cairo University, Cairo, Egypt.

Ophthalmology Department, Faculty of Medicine, Fayoum University, Fayoum, Egypt.

出版信息

Clin Ophthalmol. 2020 Oct 29;14:3583-3589. doi: 10.2147/OPTH.S262916. eCollection 2020.

Abstract

PURPOSE

The purpose of this study was to correlate between the axial length of the globe and the insertion site of horizontal extraocular muscles using swept-source anterior segment optical coherence tomography (SS-ASOCT), with posing an equation to calculate the muscle insertion site from the axial length.

METHODS

The study design was observational and cross-sectional. It was performed on 157 eyes of 157 healthy subjects. The distance of the medial rectus (MR) and the lateral rectus (LR) insertion sites from the limbus were measured using SS-ASOCT. The insertion sites' distances were correlated to the axial length (hypermetropes < 22.5 mm, myopes > 24.5). Correlation between numerical variables was done by Pearson's correlation coefficient and confirmed by linear regression analysis and scatter diagrams.

RESULTS

The mean MR insertion site was 5.47 ± 0.19 mm in hypermetropes versus 5.68 ± 0.23 mm in myopes, whereas the mean LR insertion site was 6.81± 0.23 mm in hyperopes versus 7.08 ± 0.16 mm in myopes. The axial length showed a moderate positive, but significant, correlation to the insertional position for the medial and lateral rectus muscles (MR: =0.417, p<0.001; LR: =0.410, p<0.001).

CONCLUSION

Comparing the horizontal extraocular muscle insertion site to axial length using SS-ASOCT showed a significant positive correlation. The model equation for MR insertion: MR (mm) = 4.522 + 0.045 (AXL in mm) with an R = 0.437, R= 0.191, F=12.071, P<0.001. The model equation for LR insertion: LR (mm) = 5.72 + 0.048 (AXL in mm) with an R = 0.438, R= 0.192, F=12.116, P<0.001.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7e0a/7605956/23a1dcccc406/OPTH-14-3583-g0001.jpg

相似文献

1
Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT.
Clin Ophthalmol. 2020 Oct 29;14:3583-3589. doi: 10.2147/OPTH.S262916. eCollection 2020.
2
Spectral domain optical coherence tomography to assess the insertion of extraocular rectus muscles.
J AAPOS. 2016 Jun;20(3):201-5. doi: 10.1016/j.jaapos.2016.02.011. Epub 2016 May 7.
5
Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography.
PLoS One. 2020 Dec 23;15(12):e0243382. doi: 10.1371/journal.pone.0243382. eCollection 2020.
6
Do rectus muscle parameters vary between emmetropes and myopes?
Ophthalmic Physiol Opt. 2021 Nov;41(6):1300-1307. doi: 10.1111/opo.12890. Epub 2021 Sep 22.
8
Assessment of extraocular muscle thickness and correlation study using optical coherence tomography.
Arch Soc Esp Oftalmol (Engl Ed). 2018 Aug;93(8):392-397. doi: 10.1016/j.oftal.2017.12.017. Epub 2018 Feb 3.
10
Horizontal Extraocular Muscle and Scleral Anatomy in Children: A Swept-Source Anterior Segment Optical Coherence Tomography Study.
Korean J Ophthalmol. 2018 Apr;32(2):83-88. doi: 10.3341/kjo.2017.0034. Epub 2018 Mar 19.

引用本文的文献

1
Clinical Role of Swept Source Anterior Segment Optical Coherence Tomography in Strabismus Re-Operation with Lost Surgical Details.
Clin Ophthalmol. 2021 Aug 25;15:3581-3591. doi: 10.2147/OPTH.S328215. eCollection 2021.
2
Relationship between Axial Length and Corneo-Scleral Topography: A Preliminary Study.
Diagnostics (Basel). 2021 Mar 18;11(3):542. doi: 10.3390/diagnostics11030542.

本文引用的文献

1
Spectral domain optical coherence tomography to assess the insertion of extraocular rectus muscles.
J AAPOS. 2016 Jun;20(3):201-5. doi: 10.1016/j.jaapos.2016.02.011. Epub 2016 May 7.
4
Axial length, anterior chamber depth-a study in different age groups and refractive errors.
J Clin Diagn Res. 2013 Oct;7(10):2211-2. doi: 10.7860/JCDR/2013/7015.3473. Epub 2013 Oct 5.
6
P. J. Tillaux: of the way the muscles insert onto the sclera. 1877.
Strabismus. 2008;16(4):174-5. doi: 10.1080/09273970802637558.
7
Evaluation of vertical rectus muscles using ultrasound biomicroscopy.
J AAPOS. 2008 Apr;12(2):128-31. doi: 10.1016/j.jaapos.2007.06.019. Epub 2008 Mar 10.
8
Ultrasound of the horizontal rectus muscle insertion sites: implications in preoperative assessment of strabismus.
Invest Ophthalmol Vis Sci. 2003 Feb;44(2):618-22. doi: 10.1167/iovs.02-0112.
9
Evaluation of the ultrasound biomicroscope in strabismus surgery.
J AAPOS. 2002 Jun;6(3):187-90. doi: 10.1067/mpa.2002.122365.
10
MRI measurements of normal extraocular muscles and other orbital structures.
Graefes Arch Clin Exp Ophthalmol. 2000 May;238(5):393-404. doi: 10.1007/s004170050370.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验