Chen Z Z, Zhou W J, Ren J Y, Liu Z H
Department of Oral Implantology, Yantai Stomatological Hospital Affiliated to Binzhou Medical College, Yantai 264001, China.
Zhonghua Kou Qiang Yi Xue Za Zhi. 2020 Nov 9;55(11):864-870. doi: 10.3760/cma.j.cn112144-20200811-00455.
To evaluate long-term clinical outcome of implant-supported fixed prosthesis with the guidance of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical template in old patients. Fifteen 50-67(58.6±5.3) year-old patients (11 males and 4 females) who received the digital implant surgery with the guidance of CAD/CAM surgical template and implant-supported fixed prosthesis in Department of Oral Implantology, Yantai Stomatological Hospital Affiliated to Binzhou Medical College from August, 2013 to Janurary, 2016 were included. There are 15 edentulous maxillas, 8 edentulous mandibles on which 145 implants were placed in total. After the placement of implant, the accuracy of CAD/CAM surgical template was assessed by comparing the post-operative 3-dimensional location of implant with the pre-operative design. The 5-year survival rate of implant and prosthesis was recorded, and marginal bone loss around implants and the development of complication were evaluated by radiological and clinical examination respectively. The result on accuracy of CAD/CAM surgical template showed that deviations in neck and apex of implants were (0.78±0.59) and (1.38±0.63) mm respectively, depth deviation was (0.65±0.35) mm and angle deviation was 4.12°±2.77°. The 5-year cumulative survival rate of implants was 98.6%(143/145). In all 145 implants, the prevalence of implant-related biological complication was 4.1%(6/145). The prosthesis-related mechanical complication rate was 57%(13/23). After 5-year function, mean peri-implant bone loss was (0.69±0.35) mm. This 5-year follow-up retrospective study showed that implant-supported fixed prosthesis with the guidance of CAD/CAM surgical template in middle aged and elderly patients could achieve good long-term clinical outcome and patient satisfaction.
评估计算机辅助设计/计算机辅助制造(CAD/CAM)手术模板引导下的种植体支持固定修复体在老年患者中的长期临床疗效。纳入2013年8月至2016年1月在滨州医学院附属烟台口腔医院口腔种植科接受CAD/CAM手术模板引导下的数字化种植手术及种植体支持固定修复体的15例年龄为50 - 67(58.6±5.3)岁的患者(男性11例,女性4例)。共有15例上颌无牙颌、8例下颌无牙颌,共植入145枚种植体。种植体植入后,通过比较种植体术后三维位置与术前设计来评估CAD/CAM手术模板的准确性。记录种植体和修复体的5年生存率,并分别通过影像学和临床检查评估种植体周围的边缘骨吸收及并发症的发生情况。CAD/CAM手术模板准确性结果显示,种植体颈部和根尖的偏差分别为(0.78±0.59)和(1.38±0.63)mm,深度偏差为(0.65±0.35)mm,角度偏差为4.12°±2.77°。种植体的5年累积生存率为98.6%(143/145)。在所有145枚种植体中,种植体相关生物并发症的发生率为4.1%(6/145)。修复体相关机械并发症发生率为57%(13/23)。5年功能随访后,种植体周围平均骨吸收为(0.69±0.35)mm。这项5年随访的回顾性研究表明,CAD/CAM手术模板引导下的种植体支持固定修复体在中老年患者中可取得良好的长期临床疗效及患者满意度。