Division of Nephrology, Department of Medicine, National University Hospital, Singapore.
Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.
Semin Dial. 2021 Jul;34(4):300-308. doi: 10.1111/sdi.12951. Epub 2021 Feb 8.
Polyethyleneimine-layered membrane with grafted heparin (oXiris) may improve filter life during continuous renal replacement therapy (CRRT) in addition to its immunoadsorptive capability, compared with that of conventional membrane. In this single center, prospective, open-label pilot study, we randomized critically ill patients with bleeding risk who underwent anticoagulation-free CRRT, to commence with oXiris or M150 filter with sequential crossover. We examined the filter life with each circuit and its effect on systemic coagulation parameters. We randomized 11 and nine patients to commence CRRT with oXiris and M150 respectively, with 19 oXiris and 20 M150 filter-circuits in all. Patient profiles in both arms were comparable for illness severity and comorbidities. Median filter lives for oXiris versus M150 circuits were 13 h versus 18 h (p = 0.10). Among 11 patients with paired crossover filters, filter lives for 14 oXiris-M150 circuit pairs were 13 h versus 16 h (p = 0.27), and corresponding transmembrane pressures increased to 111 mmHg versus 75 mmHg by 12 h (p = 0.02). Patients' coagulation parameters were comparable following both filter-circuits. CRRT with oXiris (vs. M150) was independently associated with shorter filter life, adjusted for prescribed dose, vascular access, and coagulopathy. Use of oXiris did not prolong filter life over conventional membrane with no evidence of systemic heparin exposure; significant membrane clogging is observed by 12 h with oXiris.
与传统膜相比,接枝肝素的聚乙烯亚胺层膜(oXiris)除了具有免疫吸附能力外,还可能在连续肾脏替代治疗(CRRT)中改善滤器寿命。在这项单中心、前瞻性、开放标签的初步研究中,我们将有出血风险且接受无抗凝 CRRT 的危重症患者随机分为两组,分别使用 oXiris 或 M150 过滤器进行序贯交叉。我们检查了每个回路的滤器寿命及其对全身凝血参数的影响。我们分别将 11 名和 9 名患者随机分配到 oXiris 和 M150 开始 CRRT,总共进行了 19 次 oXiris 和 20 次 M150 过滤器循环。在两个治疗组中,患者的病情严重程度和合并症相似。oXiris 与 M150 回路的中位滤器寿命分别为 13 小时与 18 小时(p=0.10)。在 11 名接受配对交叉滤器的患者中,14 对 oXiris-M150 回路的滤器寿命分别为 13 小时与 16 小时(p=0.27),12 小时时相应的跨膜压力分别增加到 111mmHg 与 75mmHg(p=0.02)。两组患者的凝血参数无差异。校正剂量、血管通路和凝血障碍后,oXiris(与 M150 相比)与滤器寿命较短独立相关。与传统膜相比,oXiris 的使用并未延长滤器寿命,且无证据表明全身肝素暴露;oXiris 在 12 小时时即可观察到显著的膜堵塞。