Xi'an Research Institute of High-Tech, Xi'an, People's Republic of China.
J Radiol Prot. 2021 Jun 1;41(2). doi: 10.1088/1361-6498/abf94e.
There is currently general concern over low-level radioactive wastewater from the development of nuclear industry. In this paper, a method based on an ultralow-level liquid scintillation spectrometer for measuring uranium radioactivity in low-level radioactive wastewater is proposed. This method can easily and quickly measure the radioactivity level of uranium in samples and can even distinguish the main isotopes of uranium. The liquid scintillation method directly provides results in units of radioactivity activity concentration, which are more convenient for comparison with relevant national standards to determine whether the emission standards are met. The lowest limit of detection of this method is 0.014 Bq lwithin 600 min.
目前,人们普遍关注核工业发展产生的低水平放射性废水。本文提出了一种基于超低水平液体闪烁谱仪测量低水平放射性废水中铀放射性的方法。该方法可以方便、快速地测量样品中铀的放射性水平,甚至可以区分铀的主要同位素。液体闪烁法直接提供放射性活度浓度的结果,更便于与相关国家标准进行比较,以确定是否符合排放标准。该方法的最低检测限为 0.014 Bq l,测量时间为 600 min。