3T磁共振成像(MRI)下基底节区穿支动脉的速度和搏动性测量:与7T MRI的对比研究

Velocity and Pulsatility Measures in the Perforating Arteries of the Basal Ganglia at 3T MRI in Reference to 7T MRI.

作者信息

Arts Tine, Meijs Timion A, Grotenhuis Heynric, Voskuil Michiel, Siero Jeroen, Biessels Geert Jan, Zwanenburg Jaco

机构信息

Department of Radiology, Center for Image Sciences, University Medical Center Utrecht, Utrecht, Netherlands.

Department of Cardiology, University Medical Center Utrecht, Utrecht, Netherlands.

出版信息

Front Neurosci. 2021 Apr 26;15:665480. doi: 10.3389/fnins.2021.665480. eCollection 2021.

Abstract

Cerebral perforating artery flow velocity and pulsatility can be measured using 7 tesla (T) MRI. Enabling these flow metrics on more widely available 3T systems would make them more employable. It is currently unknown whether these measurements can be performed at 3T MRI due to the lower signal-to-noise ratio (SNR). Therefore, the aim of this study is to investigate if flow velocity and pulsatility in the perforating arteries of the basal ganglia (BG) can be measured at 3T MRI and assess the agreement with 7T MRI measurements as reference. Twenty-nine subjects were included, of which 14 patients with aortic coarctation [median age 29 years (21-72)] and 15 controls [median age 27 years (22-64)]. Using a cardiac-gated 2D phase-contrast MRI sequence BG perforating arteries were imaged at 3T and 7T MRI and perforating artery density (N , #/cm), flow velocity (V , cm/s) and pulsatility index (PI) were determined. Agreement between scanner modalities was assessed using correlation and difference plots with linear regression. A -value ≤ 0.05 indicated statistical significance. It was shown that perforating artery flow velocity and pulsatility can be measured at 3T MRI (N = 0.21 ± 0.11; V = 6.04 ± 1.27; PI = 0.49 ± 0.19), although values differed from 7T MRI measurements (N = 0.95 ± 0.21; V = 3.89 ± 0.56; PI = 0.28 ± 0.08). The number of detected arteries was lower at 3T (5 ± 3) than 7T MRI (24 ± 6), indicating that 3T MRI is on average a factor 4.8 less sensitive to detect cerebral perforating arteries. Comparison with 7T MRI as reference showed some agreement in N , but little to no agreement for V and PI. Equalizing the modalities' sensitivity by comparing the detected arteries on 7T MRI with the highest velocity with all vessels detected on 3T MRI, showed some improvement in agreement for PI, but not for V . This study shows that it is possible to measure cerebral perforating artery flow velocity and pulsatility at 3T MRI, although an approximately fivefold sample size is needed at 3T relative to 7T MRI for a given effect size, and the measurements should be performed with equal scanner field strength and protocol.

摘要

可使用7特斯拉(T)磁共振成像(MRI)测量脑穿支动脉的血流速度和搏动性。若能在更广泛使用的3T系统上实现这些血流指标测量,将使其更具实用性。目前尚不清楚由于较低的信噪比(SNR),这些测量能否在3T MRI上进行。因此,本研究的目的是调查在3T MRI上能否测量基底节(BG)穿支动脉的血流速度和搏动性,并评估与作为参考的7T MRI测量结果的一致性。纳入了29名受试者,其中14例主动脉缩窄患者[中位年龄29岁(21 - 72岁)]和15名对照者[中位年龄27岁(22 - 64岁)]。使用心脏门控二维相位对比MRI序列,在3T和7T MRI上对BG穿支动脉进行成像,并确定穿支动脉密度(N ,条/cm)、血流速度(V ,cm/s)和搏动指数(PI)。使用相关性和带有线性回归的差异图评估不同扫描设备之间的一致性。P值≤0.05表示具有统计学意义。结果表明,在3T MRI上可以测量穿支动脉的血流速度和搏动性(N = 0.21 ± 0.11;V = 6.04 ± 1.27;PI = 0.49 ± 0.19),尽管这些值与7T MRI测量结果不同(N = 0.95 ± 0.21;V = 3.89 ± 0.56;PI = 0.28 ± 0.08)。3T时检测到的动脉数量(5 ± 3)低于7T MRI(24 ± 6),表明3T MRI检测脑穿支动脉的敏感性平均低4.8倍。与作为参考的7T MRI比较显示,在N 方面有一定一致性,但在V 和PI方面几乎没有一致性。通过将7T MRI上检测到的速度最高的动脉与3T MRI上检测到的所有血管进行比较来均衡不同设备的敏感性,结果显示PI的一致性有一定改善,但V 没有。本研究表明,在3T MRI上可以测量脑穿支动脉的血流速度和搏动性,尽管对于给定的效应量,相对于7T MRI,3T时需要大约五倍的样本量,并且测量应在相同的扫描设备场强和协议下进行。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e23d/8107291/f25622a05833/fnins-15-665480-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验