超声测量慢性下腰痛患者侧腹部和腰部多裂肌的可靠性:横断面测试-再测试研究。

Reliability of ultrasound measurement of the lateral abdominal and lumbar multifidus muscles in individuals with chronic low back pain: A cross-sectional test-retest study.

机构信息

Department of Physiotherapy, School of Rehabilitation, Tehran University of Medical Sciences, (TUMS), Tehran, Iran.

Department of Physiotherapy, School of Rehabilitation, Tehran University of Medical Sciences, International Campus (TUMS, IC-TUMS), Brain and Spinal Injury Research Center (BASIR), Tehran, Iran.

出版信息

J Bodyw Mov Ther. 2021 Apr;26:394-400. doi: 10.1016/j.jbmt.2020.12.029. Epub 2020 Dec 24.

Abstract

OBJECTIVES

Ultrasound (US) imaging has been suggested to evaluate the morphology and function of trunk muscles; however, little is known about the reliability of the US measures in patients with chronic low back pain (CLBP). This study aimed to evaluate intrarater reliability of US imaging of the lateral abdominal and lumbar multifidus muscles in individuals with nonspecific CLBP.

METHODS

In this cross-sectional study, intrarater within-day and between-day reliability of US measurements of the transversus abdominis, internal oblique, external oblique and lumbar multifidus (at the L3-L4, L4-L5, and L5-S1 levels) muscles were obtained on both sides. The resting and contracted thickness and contraction ratio of each muscle were measured in 21 individuals with nonspecific CLBP.

RESULTS

All US measurements of the lateral abdominal and lumbar multifidus muscles demonstrated good to excellent within-day (Intraclass correlation coefficients (ICCs: 0.80-0.98) and between-day (ICCs: 0.80-0.97) reliability. The standard error of the measurement (SEMs) and minimal detectable change (MDCs) of the lateral abdominal muscles on both sides ranged 0.5-1.6 mm and 0.4-4.4 mm, respectively. The SEMs and MDCs of the LM muscles on both sides ranged 1.1-2.7 mm and 2.86-7.49 mm, respectively.

CONCLUSION

The findings indicate that US imaging has good to high intrarater within- and between-day reliability for assessing absolute thickness and contraction ratio of the trunk muscles on both right and left sides in patients with nonspecific CLBP. The vertical alignment of the US transducer is a reliable method for assessing the lateral abdominal muscles.

摘要

目的

超声(US)成像已被用于评估躯干肌肉的形态和功能;然而,对于慢性下腰痛(CLBP)患者,US 测量的可靠性知之甚少。本研究旨在评估非特异性 CLBP 患者侧腹部和腰部多裂肌的 US 成像的内部观察者可靠性。

方法

在这项横断面研究中,对 21 名非特异性 CLBP 患者的两侧横突腹直肌、内斜肌、外斜肌和多裂肌(在 L3-L4、L4-L5 和 L5-S1 水平)的 US 测量进行内部观察者日内和日间可靠性。测量了每块肌肉的静息和收缩厚度以及收缩比。

结果

侧腹部和腰部多裂肌的所有 US 测量均表现出良好到极好的日内(组内相关系数(ICCs:0.80-0.98)和日间(ICCs:0.80-0.97)可靠性。双侧侧腹肌的测量标准误差(SEMs)和最小可检测变化(MDCs)分别为 0.5-1.6 毫米和 0.4-4.4 毫米。双侧 LM 肌肉的 SEMs 和 MDCs 分别为 1.1-2.7 毫米和 2.86-7.49 毫米。

结论

研究结果表明,US 成像具有良好到高度的内部观察者日内和日间可靠性,可用于评估非特异性 CLBP 患者双侧躯干肌肉的绝对厚度和收缩比。US 换能器的垂直对准是评估侧腹肌的可靠方法。