Laser-induced thermal effects can preclude a safe histological evaluation of biopsy resection margins. The aim of this study was to evaluate the suitability of a 976 nm diode laser in oral soft tissue biopsies in an study.
A 976 nm diode laser (Solase®, Lazon Medical Laser, China) has been used in the contact mode, using a 400 m fiber tip, at different parameters from 4 to 6 W in the continuous wave (CW), with a fluence between 3184 and 4777 J/cm, and pulsed wave (PW) mode, with a fluence between 318,4 and 477,7 J/cm, to obtain 30 samples from fresh pig cadaver tongues. All specimens were subdivided into 6 groups (from A to F), and each group consisted of 5 samples. Two sections were obtained from each sample. A histological analysis was performed using an optical microscope at magnifications of 5x and 10x. Statistical analysis was carried out using Kruskal-Wallis and Dunn's tests.
The results showed that histological readability was optimal in all the samples. The thermal damage was negligible in all groups. The average thermal damage was 208.40 ± 133.81 m in the epithelial tissue and 330.14 ± 147.45 m in the connective tissue. The statistical analysis showed no differences between the groups ( > 0.05).
A 976 nm diode laser demonstrated good surgical effectiveness that provoked little peripheral damage in the cut edges and allowed a safe histological diagnosis. . In oral pathology, many times, there is fear in using the laser to remove some lesions due to its thermal effect on the tissues close to the lesion. This effect is always present in the use of the laser, but the intent is to minimize this effect to have as little alteration as possible on the surrounding tissues.
激光诱导的热效应可能会妨碍对活检切除边缘进行安全的组织学评估。本研究的目的是在一项研究中评估976纳米二极管激光在口腔软组织活检中的适用性。
使用976纳米二极管激光(Solase®,拉佐恩医用激光,中国),采用接触模式,使用400微米的光纤尖端,在连续波(CW)模式下以4至6瓦的不同参数,能量密度在3184至4777焦/平方厘米之间,以及脉冲波(PW)模式下,能量密度在318.4至477.7焦/平方厘米之间,从新鲜猪尸体舌头获取30个样本。所有标本被分成6组(从A到F),每组由5个样本组成。每个样本获取两片切片。使用光学显微镜在5倍和10倍放大倍数下进行组织学分析。使用Kruskal-Wallis和邓恩检验进行统计分析。
结果表明,所有样本的组织学可读性均最佳。所有组的热损伤均可忽略不计。上皮组织的平均热损伤为208.40±133.81微米,结缔组织的平均热损伤为330.14±147.45微米。统计分析表明各组之间无差异(P>0.05)。
976纳米二极管激光显示出良好的手术效果,在切缘引起的周边损伤很小,并能实现安全的组织学诊断。在口腔病理学中,由于激光对病变周围组织的热效应,很多时候人们在使用激光切除某些病变时会有所顾虑。这种效应在激光使用中始终存在,但目的是尽量减少这种效应,以使周围组织的改变尽可能小。