Suppr超能文献

机器人辅助磁共振成像-超声融合经会阴靶向活检。

Robot-assisted Magnetic Resonance Imaging-ultrasound Fusion Transperineal Targeted Biopsy.

机构信息

Department of Urology, Singapore General Hospital, Singapore.

Department of Urology, Singapore General Hospital, Singapore.

出版信息

Urology. 2021 Sep;155:46. doi: 10.1016/j.urology.2021.06.008. Epub 2021 Jun 26.

Abstract

OBJECTIVE

To demonstrate the key steps to perform robot-assisted magnetic resonance imaging-ultrasound fusion transperineal prostate biopsy.

MATERIALS AND METHODS

Men with suspicion of prostate cancer underwent 3-Tesla multi-parametric MRI and were assigned a Prostate Imaging Reporting and Data System v2 score (PI-RADS). The prostate outline and suspicious lesions were marked by our radiologist using our software to produce a 3-dimensional prostate MRI model. All biopsies were performed under general anaesthesia and the real-time transrectal ultrasound model is created and subsequently fused with the MRI model using non-rigid software fusion. Transperineal targeted and systematic biopsy were then performed under stereotactic guidance using our robot-assisted prostate biopsy platform. Our clinically significant prostate cancer (Grade group ≥2) detection rates were previously described. RESULTS: Out of the 433 patients who underwent targeted and systematic biopsy, clinically-significant cancer detection rate was 46% (85% for PI- RADS 5 vs 38% for PI-RADS 4 vs 16% for PI-RADS 3; P < .001). Our overall complication rate was 13%, out of which the majority were Clavien-Dindo I (99%). The most common complications encountered were urinary retention (10%) and significant gross hematuria requiring bladder irrigation (2%). A higher prostate volume was associated with greater odds of urinary retention (OR 1.4, 95% CI: 1.21-1.65, P < .001 for every 10 mL increase in prostate volume). There was only 1 reported case of mild urinary tract infection.

CONCLUSION

Robot-assisted transperineal prostate biopsy has established itself as a reliable and accurate method of prostate cancer detection with minimal morbidity.

摘要

目的

演示机器人辅助磁共振成像-超声融合经会阴前列腺活检的关键步骤。

材料与方法

怀疑患有前列腺癌的男性患者接受 3T 多参数 MRI 检查,并根据前列腺成像报告和数据系统第 2 版(PI-RADS)评分进行分配。我们的放射科医生使用我们的软件对前列腺轮廓和可疑病变进行标记,以生成 3 维前列腺 MRI 模型。所有活检均在全身麻醉下进行,实时经直肠超声模型创建后,使用非刚性软件融合与 MRI 模型融合。然后在我们的机器人辅助前列腺活检平台的立体定向引导下进行经会阴靶向和系统活检。我们之前已经描述了我们的临床显著前列腺癌(分级组≥2)检测率。

结果

在接受靶向和系统活检的 433 例患者中,临床显著癌症检出率为 46%(PI-RADS 5 为 85%,PI-RADS 4 为 38%,PI-RADS 3 为 16%;P<0.001)。我们的总并发症发生率为 13%,其中大多数为 Clavien-Dindo I 级(99%)。最常见的并发症是尿潴留(10%)和需要膀胱冲洗的明显肉眼血尿(2%)。前列腺体积越大,尿潴留的可能性越大(OR 1.4,95%CI:1.21-1.65,前列腺体积每增加 10mL,P<0.001)。只有 1 例报告为轻度尿路感染。

结论

机器人辅助经会阴前列腺活检已成为一种可靠且准确的前列腺癌检测方法,其发病率较低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验