通过超分辨率提高X射线断层扫描的分辨率。

Improved resolution in x-ray tomography by super-resolution.

作者信息

Dreier Till, Peruzzi Niccolò, Lundström Ulf, Bech Martin

出版信息

Appl Opt. 2021 Jul 10;60(20):5783-5794. doi: 10.1364/AO.427934.

Abstract

In this paper, super-resolution imaging is described and evaluated for x-ray tomography and is compared with standard tomography and upscaling during reconstruction. Blurring is minimized due to the negligible point spread of photon counting detectors and an electromagnetically movable micro-focus x-ray spot. Scans are acquired in high and low magnification geometry, where the latter is used to minimize penumbral blurring from the x-ray source. Sharpness and level of detail can be significantly increased in reconstructed slices to the point where the source size becomes the limiting factor. The achieved resolution of the different methods is quantified and compared using biological samples via the edge spread function, modulation transfer function, and Fourier ring correlation.

摘要

本文介绍并评估了用于X射线断层扫描的超分辨率成像,并将其与标准断层扫描以及重建过程中的放大处理进行了比较。由于光子计数探测器的点扩散可忽略不计以及电磁可移动微焦点X射线源,模糊效应被降至最低。扫描在高倍和低倍几何条件下进行,其中低倍几何条件用于将X射线源的半影模糊降至最低。重建切片中的清晰度和细节水平可显著提高,直至源尺寸成为限制因素。通过边缘扩散函数、调制传递函数和傅里叶环相关,使用生物样本对不同方法实现的分辨率进行了量化和比较。