Chen Xun, Han Tian, Zhao Wuxiao, Wang Xuanqi, Xu Yilin, Cheng Mingrui, Wang Xiaoying, Zhou Xingtao
Eye, Ear, Nose and Throat Hospital, Fudan University, No. 19 BaoQing Road, XuHui District, Shanghai, 200031, China.
National Health Commission Key Lab of Myopia (Fudan University), Shanghai, China.
Ophthalmol Ther. 2021 Dec;10(4):947-955. doi: 10.1007/s40123-021-00386-7. Epub 2021 Aug 30.
To assess the differences between the horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements, their related factors, and their effects on vault after implantable Collamer lens (ICL) implantation.
This retrospective study included 429 eyes of 429 patients (145 men and 284 women with a mean age of 29.22 ± 8.06 years) who underwent ICL implantation. The choice of the ICL size depended on the WTW diameter and anterior chamber depth (ACD). The information of WTW diameter, STS diameters, ACD, and their relationships on vault were analyzed.
Horizontal STS and WTW diameters were correlated (r = 0.71, P < 0.001). The mean difference between the STS and WTW diameters was -0.02 ± 0.33 (-1.36 to 1.11) mm. The average vaults of the STS-WTW < -0.1 group, - 0.1 ≤ STS-WTW ≤ 0.1 group, and STS-WTW > 0.1 group were 558.36 ± 163.58 (250-1100) μm, 513.10 ± 121.42 (190-850) μm, and 469.01 ± 133.23 (120-750) μm, respectively. There were significant differences between these groups (P < 0.05). STS-WTW was correlated with the horizontal STS diameter (r = 0.30, P < 0.001), the WTW diameter (r = -0.17, P = 0.001), and the ACD (r = 0.17, P < 0.001). When the WTW diameter was further away from 11.08 to 12.51 mm or the ACD was further away from 2.81 to 3.74 mm, the difference between the STS and WTW diameters was larger and the correlation between the STS and WTW diameters was weaker.
The difference between the WTW and STS diameters was larger for cases with a WTW diameter or anterior chamber depth outside a certain range; this may be associated with an undesirable vault after ICL implantation. Special attention should be paid to these patients.
评估水平白对白(WTW)直径与水平沟对沟(STS)直径测量值之间的差异、它们的相关因素以及可植入式Collamer晶状体(ICL)植入术后对拱高的影响。
这项回顾性研究纳入了429例接受ICL植入术患者的429只眼(145例男性和284例女性,平均年龄29.22±8.06岁)。ICL尺寸的选择取决于WTW直径和前房深度(ACD)。分析了WTW直径、STS直径、ACD的信息及其与拱高的关系。
水平STS直径与WTW直径相关(r = 0.71,P < 0.001)。STS直径与WTW直径的平均差值为-0.02±0.33(-1.36至1.11)mm。STS-WTW < -0.1组、-0.1≤STS-WTW≤0.1组和STS-WTW > 0.1组的平均拱高分别为558.36±163.58(250 - 1100)μm、513.10±121.42(190 - 850)μm和469.01±133.23(120 - 750)μm。这些组之间存在显著差异(P < 0.05)。STS-WTW与水平STS直径(r = 0.30,P < 0.001)、WTW直径(r = -0.17,P = 0.001)和ACD(r = 0.17,P < 0.001)相关。当WTW直径进一步远离11.08至12.51mm或ACD进一步远离2.81至3.74mm时,STS直径与WTW直径之间的差异更大,且STS直径与WTW直径之间的相关性更弱。
对于WTW直径或前房深度超出一定范围的病例,WTW直径与STS直径之间的差异更大;这可能与ICL植入术后不理想的拱高有关。应特别关注这些患者。