Suppr超能文献

[正常人群口咽感觉功能的检测]

[Detection of oropharyngeal sensory function in normal population].

作者信息

Liu X L, Li X Y, Xu W

机构信息

Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China Department of Otorhinolaryngology Head and Neck Surgery, Chongqing General Hospital, University of Chinese Academy of Sciences, Chongqing 401147, China.

Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China.

出版信息

Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2021 Aug 7;56(8):830-836. doi: 10.3760/cma.j.cn115330-20200831-00713.

Abstract

To study the oropharyngeal sensory function by Current Perception Threshold(CPT) detection, to explore the detection method of oropharyngeal sensory function in normal population, and to analyze the possible influencing factors. Fifty-eight normal subjects were included prospectively in this study. Age, gender, body mass index (BMI) were collected. The age of the subjects ranged from 20 to 76 (43.27±13.52) years old. There were 34 females with 17 in childbearing period and 17 in menopause; and 24 males were included.In all the cases, 6 cases were in low BMI, 39 cases were in normal BMI, 10 cases were overweight and 3 cases were suffering from obesity. The CPT system of Neurometer was used to stimulate bilateral palatoglossal arch and tongue base.The current used was 2000 Hz, 250 Hz and 5 Hz respectively.The function of type Aβ, Aδ and C sensory nerve fibers were tested and the CPT values were recorded.The values were inversely proportional to pharyngeal sensation function.To evaluate the oropharyngeal sensory function of the subjects, the CPT values of each frequency at each testing point were compared. SPSS 25.0 software was used for statistical analysis. The CPT value of palatoglossal arch was significantly lower than that of tongue base (=-2.58,-2.65,-2.54,-2.47,-2.37,-2.77,<0.05), 2 000 Hz>250 Hz>5 Hz, and there was no significant difference between left and right sides(=-0.03,-0.51,-0.49,0.06,-0.16,0.13,>0.05). The CPT value of male was slightly higher than that of female (=0.92,1.55,0.27,0.78,1.44,1.26,0.35,0.77,1.27,0.24,0.78,0.96,>0.05). The CPT values of women in childbearing period were significantly less than those in menopausal women (=-3.90,-3.64,-2.14,-4.20,-4.28,-4.28,-3.52,-4.46,-3.41,-3.63,-4.66,-2.86,<0.05). The CPT value increased with age, and the values of all frequency of 20 to 30 years old group was significantly lower than those of subjects over 40 years old at each point (The values of bilateral palatoglossal arch at 2 000 Hz were -5.57,-6.22,-10.18,-11.00;the values of bilateral palatoglossal arch at 250 Hz were -6.39,-8.79,-6.39,-15.61;the values of bilateral palatoglossal arch at 5 Hz were -7.09, -5.57, -9.26, -15.23;the values of tongue base at 2 000 Hz were -3.11,-3.88,-7.60,-8.55;the values of tongue base at 250 Hz were -6.31,-10.59,-8.52,-10.60;the values of tongue baseat 5 Hz were -6.69,-5.09,-8.70,-7.07,<0.05).The values at all frequencies and testing points of 30-40 years old group were significantly lower than those of all subjects over 60 years old (The values of bilateral palatoglossal arch at 2 000 Hz were -10.91,-12.42;the values of bilateral palatoglossal arch at 250 Hz were -6.25,-10.87;the values of bilateral palatoglossal arch at 5 Hz were -5.53,-11.01;the values of tongue base at 2 000 Hz were -8.62,-10.12;the values of tongue base at 250 Hz were -6.89,-7.82;the values of tongue base at 5 Hz were -6.13,-6.48,<0.05). CPT can be used to evaluate oropharyngeal sensory function. The sensitivity of tongue base is lower than that of palatoglossal arch, there is no significant difference in oropharyngeal sensory function between male and female,between left and right sides. There are many factors influencing oropharyngeal sensory function. Age, hormone level changes may affect the sensitivity of oropharyngeal sensory function.

摘要

通过电流感觉阈值(CPT)检测研究口咽感觉功能,探索正常人群口咽感觉功能的检测方法,并分析可能的影响因素。本研究前瞻性纳入58例正常受试者。收集年龄、性别、体重指数(BMI)。受试者年龄范围为20至76岁(43.27±13.52岁)。其中女性34例,育龄期17例,绝经后17例;男性24例。所有病例中,低BMI者6例,正常BMI者39例,超重者10例,肥胖者3例。采用Neurometer CPT系统刺激双侧腭舌弓和舌根。所用电流分别为2000Hz、250Hz和5Hz。检测Aβ、Aδ和C型感觉神经纤维功能并记录CPT值。该值与咽部感觉功能呈反比。为评估受试者的口咽感觉功能,比较各检测点各频率的CPT值。采用SPSS 25.0软件进行统计分析。腭舌弓的CPT值显著低于舌根(=-2.58,-2.65,-2.54,-2.47,-2.37,-2.77,<0.05),2000Hz>250Hz>5Hz,左右两侧无显著差异(=-0.03,-0.51,-0.49,0.06,-0.16,0.13,>0.05)。男性的CPT值略高于女性(=0.92,1.55,0.27,0.78,1.44,1.26,0.35,0.77,1.27,0.24,0.78,0.96,>0.05)。育龄期女性的CPT值显著低于绝经后女性(=-3.90,-3.64,-2.14,-4.20,-4.28,-4.28,-3.52,-4.46,-3.41,-3.63,-4.66,-2.86,<0.05)。CPT值随年龄增加而升高,20至30岁组各点各频率的值均显著低于40岁以上受试者(双侧腭舌弓2000Hz时的值为-5.57,-6.22,-10.18,-11.00;双侧腭舌弓250Hz时的值为-6.39,-8.79,-6.39,-15.61;双侧腭舌弓5Hz时的值为-7.09,-5.57,-9.26,-15.23;舌根2000Hz时的值为-3.11,-3.88,-7.60,-8.55;舌根250Hz时的值为-6.31,-10.59,-8.52,-10.60;舌根5Hz时的值为-6.69,-5.09,-8.70,-7.07,<0.05)。30至40岁组各频率和各检测点的值均显著低于60岁以上所有受试者(双侧腭舌弓2000Hz时的值为-10.91,-12.42;双侧腭舌弓250Hz时的值为-6.25,-10.87;双侧腭舌弓5Hz时的值为-5.53,-11.01;舌根2000Hz时的值为-8.62,-10.12;舌根250Hz时的值为-6.89,-7.82;舌根5Hz时的值为-6.13,-6.48,<0.05)。CPT可用于评估口咽感觉功能。舌根的敏感性低于腭舌弓,口咽感觉功能在男性与女性之间、左右两侧之间无显著差异。影响口咽感觉功能的因素众多。年龄、激素水平变化可能影响口咽感觉功能的敏感性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验