Suppr超能文献

IV级钛及Ti-6Al-4V和Ti-13Nb-13Zr钛合金激光处理后的力学性能及残余应力测量

Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment.

作者信息

Jażdżewska Magdalena, Kwidzińska Dominika Beata, Seyda Wiktor, Fydrych Dariusz, Zieliński Andrzej

机构信息

Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdańsk University of Technology, 80-233 Gdańsk, Poland.

Office of Technical Inspection, 80-233 Gdańsk, Poland.

出版信息

Materials (Basel). 2021 Oct 22;14(21):6316. doi: 10.3390/ma14216316.

Abstract

Nowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze the properties of the obtained surface layers, the following tests were performed: scanning electron microscopy, chemical and phase composition analysis, wetting angle tests and roughness tests. The assessment of the impact of the laser modification on the internal stresses of the investigated materials was carried out by comparing the values of the stresses of the laser-modified samples to those of the reference samples. The obtained results showed increased values of tensile stresses after laser modification: the highest value was found for the Ti-6Al-4V alloy at 6.7434 GPa and the lowest for pure grade IV titanium at 3.742 GPa. After laser and heat treatment, a reduction in the stress was observed, together with a significant increase in the hardness of the tested materials, with the highest value for Ti-6Al-4V alloy at 27.723 GPa. This can provide better abrasion resistance and lower long-term toxicity, both of which are desirable when using Ti-6Al-4V and Ti-13Nb-13Zr alloys for implant materials.

摘要

如今,表面工程专注于医学应用材料的研究。钛及其合金很突出,尤其是Ti-6Al-4V和Ti-13Nb-13Zr。由纯IV级钛以及Ti-6Al-4V和Ti-13Nb-13Zr钛合金制成的样品在持续时间t = 1 ms的激光脉冲期间,通过频率f = 25 Hz、功率P = 1000 W的激光束进行处理。随后,为了分析所获得的表面层的性能,进行了以下测试:扫描电子显微镜、化学和相组成分析、润湿角测试以及粗糙度测试。通过比较激光改性样品与参考样品的应力值,对激光改性对所研究材料内应力的影响进行了评估。所得结果表明,激光改性后拉应力值增加:Ti-6Al-4V合金的最高值为6.7434 GPa,纯IV级钛的最低值为3.742 GPa。经过激光和热处理后,观察到应力降低,同时测试材料的硬度显著增加,Ti-6Al-4V合金的最高值为27.723 GPa。这可以提供更好的耐磨性和更低的长期毒性,在将Ti-6Al-4V和Ti-13Nb-13Zr合金用作植入材料时,这两者都是理想的特性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/76f8/8585406/91f739ce6c46/materials-14-06316-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验