Nuclear Medicine Department, King Saud Medical City (KSMC), Riyadh, Saudi Arabia.
Department of Radiology and Medical Imaging, Prince Sattam Bin Abdulaziz University, Alkharj, Saudi Arabia.
Appl Radiat Isot. 2022 Mar;181:110097. doi: 10.1016/j.apradiso.2022.110097. Epub 2022 Jan 6.
Staff occupational radiation exposure is limited to 20 mSv annually to preclude tissue reaction and lower risk of cancer effect. Staff occupational exposure arises during the preparation, injection, and scanning of the patients. Recent studies reported that nuclear medicine personnel might exceed the annual dose limit in high workload and poor radiation protection circumstances. Therefore, an accurate estimation of the annual dose limit is recommended. The goal of this research is to calculate the cumulative external effective dose (mSv) per year for nuclear medicine physicians, technologists, and nurses at SPECT/CT department. A total of 15 staff worked in the nuclear medicine department at King Saud Medical City (KSMC), Riyadh, Saudi Arabia were evaluated for the last six years. Tc is used more frequently for most of the patients. The procedures include renal, cardiac scintigraphy procedures. Staff dose was quantified using calibrated thermoluminecnt dosimeters (TLD-100) with an automatic TLD reader (Harshaw 6600). Exposure to ionizing radiation was evaluated in terms of deep doses (Hp(10) were evaluated. The overall average and standard deviation of the external doses for nuclear medicine physicians, technologists' and nurses were 1.8 ± 0.7, 1.9 ± 0.6, 2.0 ± 0.9, 2.2 ± 0.8, 6.0 ± 2.8, and 3.6 ± 1.3 for the years 2015,2016,2017,2018,2019, and 2020, respectively. Technologists and nurses received higher doses of compared to the nuclear medicine physicians. Technologists and nurses involved in radionuclide preparation, patients' injection, and image acquisition. Staff annual exposure is below the annual dose limits; however, this external dose is considered high compared to the current workload.
工作人员职业照射量限制在每年 20 毫希沃特以下,以防止组织反应和降低癌症效应风险。工作人员职业照射是在准备、注射和扫描患者时产生的。最近的研究报告称,核医学人员在工作量大且辐射防护条件差的情况下,可能超过年度剂量限制。因此,建议对年度剂量限制进行准确估计。本研究的目的是计算沙特阿拉伯利雅得国王萨乌德国王医疗城 (KSMC) 的单光子发射计算机断层扫描 (SPECT/CT) 部门核医学医师、技师和护士每年的累积外照射有效剂量 (毫希沃特)。在过去的六年中,对沙特阿拉伯利雅得 KSMC 的核医学部门的 15 名工作人员进行了评估。Tc 更频繁地用于大多数患者。这些程序包括肾、心脏闪烁照相程序。使用经校准的热释光剂量计 (TLD-100) 和自动 TLD 读取器 (Harshaw 6600) 对工作人员剂量进行量化。根据深部剂量 (Hp(10)) 评估电离辐射暴露。核医学医师、技师和护士的外照射剂量的总体平均值和标准差分别为 1.8±0.7、1.9±0.6、2.0±0.9、2.2±0.8、6.0±2.8 和 3.6±1.3,分别为 2015 年、2016 年、2017 年、2018 年、2019 年和 2020 年。与核医学医师相比,技师和护士接受的剂量更高。技师和护士参与放射性核素准备、患者注射和图像采集。工作人员的年照射量低于年度剂量限制;然而,与当前工作量相比,这个外照射剂量被认为是高的。