Department of Glaucoma, University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey.
Indian J Ophthalmol. 2022 Feb;70(2):558-563. doi: 10.4103/ijo.IJO_2012_21.
To compare the quantitative measurements of the anterior chamber angle (ACA) and iris parameters in patients with juvenile open-angle glaucoma (JOAG), pigmentary glaucoma (PG), and healthy controls using anterior segment optical coherence tomography (AS-OCT).
This was a retrospective, cross-sectional study of 25 eyes with JOAG, 25 eyes with PG, and 25 control eyes. Anterior chamber depth, angle-opening distance 500 and 750, trabecular-iris space 500 and 750, scleral spur angle, iris thickness (IT, measured at the thickest part), and iris bowing were obtained using AS-OCT (Visante" OCT 3.0 Model 1000, Carl Zeiss Meditec, Inc).
The quantitative ACA parameters were found to be significantly higher in JOAG and PG patients compared to healthy controls (P < 0.001); there was no significant difference between the eyes with JOAG and PG (P > 0.05). In eyes with JOAG and PG, there was significantly backward bowing of the iris in temporal and nasal angles compared to control subjects (P < 0.001). Median iris bowing was not significantly different between the patients with JOAG and PG (P > 0.05). The temporal and nasal angle iris thickness were significantly thinner in eyes with JOAG than the eyes with PG (P < 0.001) and age-matched control subjects (P < 0.001). The median IT did not differ between the patients with PG and control subjects (P > 0.05). In patients with JOAG, the intraocular pressure (IOP) was inversely correlated with IT (r = -0.43, P < 0.05).
AS-OCT provided quantitative data on the ACA and iris parameters in JOAG and PG. The evaluation of the ACA and iris structures using AS-OCT revealed higher ACA measurements and posterior bowing of the iris in patients with JOAG and PG. Furthermore, the patients with JOAG were found to have thinner IT than the ones with PG and healthy controls.
使用眼前节光学相干断层扫描(AS-OCT)比较青少年开角型青光眼(JOAG)、色素性青光眼(PG)和健康对照者前房角(ACA)和虹膜参数的定量测量。
这是一项回顾性、横断面研究,纳入 25 只 JOAG 眼、25 只 PG 眼和 25 只对照眼。使用 AS-OCT(蔡司 Visante" OCT 3.0 模型 1000)获得前房深度、房角开放距离 500 和 750、小梁虹膜空间 500 和 750、巩膜突角、虹膜厚度(最厚处测量)和虹膜弓状弯曲。
JOAG 和 PG 患者的定量 ACA 参数明显高于健康对照组(P<0.001);JOAG 眼与 PG 眼之间无显著差异(P>0.05)。JOAG 和 PG 眼的虹膜在颞角和鼻角有明显的向后弯曲,与对照组相比差异有统计学意义(P<0.001)。JOAG 和 PG 患者之间的虹膜弓状弯曲中位数无显著差异(P>0.05)。JOAG 眼的颞角和鼻角虹膜厚度明显比 PG 眼薄(P<0.001)和年龄匹配的对照组(P<0.001)。PG 患者和对照组之间的中位 IT 无差异(P>0.05)。JOAG 患者的眼压(IOP)与 IT 呈负相关(r=-0.43,P<0.05)。
AS-OCT 提供了 JOAG 和 PG 患者的 ACA 和虹膜参数的定量数据。使用 AS-OCT 评估 ACA 和虹膜结构,发现 JOAG 和 PG 患者的 ACA 测量值较高,虹膜向后弯曲。此外,JOAG 患者的 IT 比 PG 患者和健康对照组薄。