Suppr超能文献

低成本接收机在配备大地测量级天线的基站-流动站配置中的性能

Behavior of Low-Cost Receivers in Base-Rover Configuration with Geodetic-Grade Antennas.

作者信息

Sanna Giannina, Pisanu Tonino, Garau Salvatore

机构信息

Department of Civil, Environmental Engineering and Architecture, University of Cagliari, 09123 Cagliari, Italy.

National Institute for Astrophysics, Astronomical Observatory of Cagliari, 09047 Selargius, Italy.

出版信息

Sensors (Basel). 2022 Apr 5;22(7):2779. doi: 10.3390/s22072779.

Abstract

The main goal of this research was to evaluate the performances of the ZED-F9P-Ublox low-cost GNSS receiver in a base-rover real configuration. We realized a base configuration with two permanent stations based on the ZED-F9P and two geodetic antennas and the rover configuration based on another ZED-F9P and an ANN-MB-00-00 Multi-band (L1, L2/E5b/B2I) active GNSS u-blox antenna. In the calculation of the reference stations, we compared the solutions with the ZED-F9P receiver and a professional receiver. Comparison showed greater variability in the solutions, but the coordinate values were in very good agreement. Standard deviations were in the order of a few millimeters. On the rover side, two car tests were performed in two different environments, one in an extra-urban environment with a long baseline of approximately 30 km in an open sky area with varying visibility and shielded locations, the other one in an urban area around a circle approximately 10 km in diameter with the presence of buildings and open sectors. The results of the measurements were very good, with more than 95% of fixed solutions in real-time and a time to fix on reacquisition of 1 or 2 s. Moreover, real-time kinematic solutions were in good agreement with the post-processed ones, showing that less than 5% of differences were above 30 mm in the horizontal component and 100 mm in the vertical component.

摘要

本研究的主要目标是评估ZED-F9P-Ublox低成本全球导航卫星系统(GNSS)接收机在基站-流动站实际配置中的性能。我们基于ZED-F9P和两个大地测量天线实现了一个包含两个永久站的基站配置,以及基于另一个ZED-F9P和一个ANN-MB-00-00多频段(L1、L2/E5b/B2I)有源GNSS u-blox天线的流动站配置。在参考站的计算中,我们将ZED-F9P接收机的解与专业接收机的解进行了比较。比较结果显示解的变异性更大,但坐标值非常吻合。标准偏差在几毫米量级。在流动站方面,在两种不同环境中进行了两次车载测试,一次是在城郊环境中,在开阔天空区域,基线长约30公里,能见度和遮挡位置各不相同;另一次是在城市区域,围绕一个直径约10公里的圆圈,有建筑物和开阔区域。测量结果非常好,实时固定解超过95%,重新获取时的固定时间为1或2秒。此外,实时动态解与后处理解吻合良好,表明水平分量中差异超过30毫米、垂直分量中差异超过100毫米的情况不到5%。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8c18/9002666/e8c1040a15d1/sensors-22-02779-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验