Štalc Jurij, Cicchinelli Luke D, Miller Stuart, Sofka Carolyn M, Richter Martinus
Valdoltra Orthopedic Hospital, Ankaran, Slovenia.
Clínica Cándido Guillén, Vigo, Spain and Clínica Pereira, Vigo, Spain.
Foot Ankle Surg. 2022 Dec;28(8):1293-1299. doi: 10.1016/j.fas.2022.06.013. Epub 2022 Jun 23.
A bio-integrative fiber-reinforced implant (OSSIOfiber® Hammertoe Fixation Implant, OSSIO Ltd., Caesarea, Israel) for proximal interphalangeal joint (PIPJ) correction-arthrodesis showed partial bio-integration at 1-year follow-up (1FU) in a previous study. The study was prolonged to assess the bio-integration at 2-year-follow-up (2FU).
Twenty-four patients with proximal interphalangeal joint (PIPJ) correction-arthrodesis using the fiber-reinforced implant and analysed at 1FU, completed 2FU. Follow-up included clinical examination, patient reported outcomes, radiographs, MRI and bio-integration scoring. Results were compared between the 1FU and 2FU (paired t-test).
Radiographs confirmed fusion in 96 % (n = 23) at 2FU (1FU, 92 % (n = 22)). Implant was no longer visible in 21 % (n = 5), partially visible in 33 % (n = 8), and fully visible in 46 % (n = 11)(1FU, fully visible 100 % (n = 24)). The border between implant and surrounding bone was scored not visible in 88 % (n = 21) and partially visible in 12 % (n = 3) (1FU, border partially visible 100 % (n = 24)). There were no cyst formation or fluid accumulation findings 1FU/2FU. Mild bone edema was detected in 4 % (n = 1) (1FU, 29 % (n = 7)). None of the edema findings were considered as adverse implant related. The mean bio-integration score was 9.71 ± 0.69 at 2FU (1FU, 7.71 ± 0.46). The parameters of border between implant and bone and bone edema further improved at the 2FU compared to the 1FU, total bio-integration score was also higher at 2FU than 1FU (each p < 0.05).
This study demonstrates 96 % PIPJ fusion rate and increased bio-integration from 1FU to 2FU, reaching advanced bio-integration of the fiber-reinforced implant at 2FU.
在先前一项研究中,一种用于近端指间关节(PIPJ)矫正关节固定术的生物整合纤维增强植入物(OSSIOfiber®锤状趾固定植入物,以色列凯撒利亚OSSIO有限公司)在1年随访(1FU)时显示出部分生物整合。该研究延长至2年随访(2FU)以评估生物整合情况。
24例使用纤维增强植入物进行近端指间关节(PIPJ)矫正关节固定术并在1FU时进行分析的患者完成了2FU随访。随访包括临床检查、患者报告的结果、X线片、MRI和生物整合评分。对1FU和2FU的结果进行比较(配对t检验)。
X线片证实2FU时融合率为96%(n = 23)(1FU时为92%,n = 22)。21%(n = 5)的植入物不再可见,33%(n = 8)部分可见,46%(n = 11)完全可见(1FU时,100%完全可见,n = 24)。植入物与周围骨之间的边界在88%(n = 21)时评分为不可见,12%(n = 3)部分可见(1FU时,边界部分可见为100%,n = 24)。1FU/2FU时均未发现囊肿形成或液体聚集。4%(n = 1)检测到轻度骨水肿(1FU时为29%,n = 7)。所有水肿表现均不被认为与植入物相关的不良情况。2FU时平均生物整合评分为9.71±0.69(1FU时为7.71±0.46)。与1FU相比,2FU时植入物与骨之间的边界和骨水肿参数进一步改善,2FU时总生物整合评分也高于1FU(各p < 0.05)。
本研究表明PIPJ融合率为96%,且从1FU到2FU生物整合增加,在2FU时纤维增强植入物达到了高级生物整合。