OBJECTIVES

To compare to three nonlinear imaging techniques to conventional, grayscale ultrasound imaging of renal lesions.

METHODS

Twenty adults with a known renal lesion and a body mass index >25 kg/m were enrolled in this prospective, institutional review board approved study. Each subject was imaged with an Aplio 500 scanner (Canon Medical Systems, Tokyo, Japan) using grayscale ultrasound, tissue harmonic imaging (THI) and two dual-frequency, differential tissue harmonic imaging modes (DTHI and DTHI-II, respectively). In total 184 images were scored by three independent and blinded observers for detail resolution, image quality, margin delineation, and depth penetration. Quantitative contrast-to-noise ratios (CNRs) were also calculated.

RESULTS

Readers and CNR values showed that nonlinear imaging was superior to grayscale ultrasound (P < .0014). DTHI-II outperformed DTHI, THI, and grayscale ultrasound with respect to detail resolution, image quality, and margin delineation (P < .012). The depth penetration of DTHI and DTHI-II was similar (P = .16), but superior to grayscale ultrasound and THI (P < .001). Two observers saw improvements in detail resolution with DTHI-II over DTHI (P < .05), while image quality and margin delineation were considered similar by two readers (P > .07) and improved with DTHI-II by one (P < .017).

CONCLUSIONS

DTHI-II improves the imaging of renal lesions compared to DTHI, THI, and grayscale ultrasound, albeit based on a limited sample size.

摘要

目的

将三种非线性成像技术与肾脏病变的传统灰阶超声成像进行比较。

方法

本前瞻性研究经机构审查委员会批准,纳入了20名已知患有肾脏病变且体重指数>25kg/m的成年人。使用Aplio 500扫描仪(佳能医疗系统公司,东京,日本)对每位受试者进行成像,成像模式包括灰阶超声、组织谐波成像(THI)以及两种双频、差分组织谐波成像模式(分别为DTHI和DTHI-II)。由三名独立且不知情的观察者对总共184幅图像的细节分辨率、图像质量、边界描绘和深度穿透进行评分。还计算了定量对比噪声比(CNR)。

结果

读者评分和CNR值表明,非线性成像优于灰阶超声(P<.0014)。在细节分辨率、图像质量和边界描绘方面,DTHI-II优于DTHI、THI和灰阶超声(P<.012)。DTHI和DTHI-II的深度穿透相似(P = 0.16),但优于灰阶超声和THI(P<.001)。两名观察者发现DTHI-II的细节分辨率优于DTHI(P<.05),而两名读者认为图像质量和边界描绘相似(P>.07),另一名读者认为DTHI-II的图像质量和边界描绘有所改善(P<.017)。

结论

尽管样本量有限,但与DTHI、THI和灰阶超声相比,DTHI-II改善了肾脏病变的成像效果。