Department of Dentistry, Faculty of Biological and Health Sciences, Federal University of Jequitinhonha and Mucuri Valleys, Diamantina, Minas Gerais, Brazil.
Tridimensional Technologies Division, Renato Archer Information Technology Center, Dom Pedro I road (SP - 65) Km 143.6, Amarais, 13069-901, Campinas, SP, Brazil.
Comput Biol Med. 2022 Sep;148:105755. doi: 10.1016/j.compbiomed.2022.105755. Epub 2022 Jun 30.
The success of bone-implant prostheses depends on several factors, among them an adequate distribution and passive adaptation of occlusal loading.
this study evaluated the stress distribution in mandibular implant-supported prosthesis with internal connection morse taper interface, under effect of number of implants (4 or 5) and loadings (bilateral 100 N, bilateral 300 N).
the virtual models were subjected to analysis by 3D finite element method, across four experimental conditions.
The stress values were evenly distributed to the peri-implant bone and implants in all simulated conditions. Stress values did not increase in the same proportion as the increase in the applied load (from 100 to 300 N). The stress value was 1.1 times higher on the implants and nearly doubled (1.5-2 times) on the peri-implant bone.
For mandibular implant-supported prosthesis, the morse taper interface is strongly recommended, with similar mechanical demand for four and five implants in both loading conditions. Five implants offered no additional benefit over four implants. The commercial pure titanium frameworks presented stress values close to the yield strength of the metal, especially at the intersection with the cantilever.
骨植入物假体的成功取决于多个因素,其中包括咬合负荷的适当分布和被动适应。
本研究评估了带有内部连接莫氏锥度接口的下颌植入物支持假体在种植体数量(4 或 5 个)和负荷(双侧 100N,双侧 300N)的影响下的应力分布。
通过三维有限元法对虚拟模型进行分析,共进行了四种实验条件的模拟。
在所有模拟条件下,骨和种植体周围的骨的应力值分布均匀。在相同的负荷增加(从 100N 增加到 300N)下,应力值并没有成比例增加。在植入物上的应力值增加了 1.1 倍,在植入物周围的骨上增加了近两倍(1.5-2 倍)。
对于下颌植入物支持的假体,莫氏锥度接口是强烈推荐的,在两种负荷条件下,四和五个植入物具有相似的机械需求。五个植入物并没有比四个植入物提供额外的益处。商用纯钛框架的应力值接近金属的屈服强度,特别是在与悬臂相交的地方。