Suppr超能文献

采用负载锆基金属有机框架的针管捕集装置进行苯丙胺衍生物的尿液生物监测。

Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal-organic framework.

机构信息

Department of Occupational Health Engineering, School of Health, Research Center for Health Sciences, Larestan University of Medical Sciences, Larestan, Iran.

Department of Occupational Health, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Science, Gonabad, Iran.

出版信息

Sci Rep. 2022 Aug 11;12(1):13702. doi: 10.1038/s41598-022-17861-1.

Abstract

In this research, zirconium-based metal-organic framework was utilized as a novel and efficient porous adsorbent for headspace extraction of Amphetamine, Methamphetamine, and Fenfluramine from the urine samples by a needle trap device (NTD). The Zr-UiO-66-PDC was electrosynthesized at the green conditions and characterized by various analyses such as FT-IR, XRD, FE-SEM, EDS, and elemental mapping techniques. Then, the effective parameters on the NTD efficiency such as salt content, pH, extraction/desorption temperature and time were evaluated and optimized by response surface methodology. The optimal extraction of amphetamine compounds was accomplished in 50 min at 70 ºC at the situation with NaCl content of 27% and pH: 11.90. The limit of detection, and limit of quantification factors were determined to be 0.06-0.09 and 0.5-0.8 ng mL, respectively. Furthermore, the precision and accuracy (intra- and inter-day) of the employed procedure in the term of relative standard deviation (RSD) were calculated in the range of 8.0-9.0% and 6.8-9.8%, respectively. Also, the recovery percent of the extracted analytes were concluded in the range of 95.0-97.0% after 10 days from the sampling and storage at 4 °C. Finally, the proposed procedure was involved in the analysis of amphetamine compounds in the real urine samples. These results were proved the proposed Zr-UiO-66-PDC@HS-NTD technique coupled with GC-FID can be used as an eco-friendly, fast-response, sensitive, and efficient drug test procedure for trace analysis of the amphetamine compounds in urine samples.

摘要

在这项研究中,采用基于锆的金属有机骨架作为一种新型高效多孔吸附剂,通过针阱装置(NTD)从尿液样品中对头状安非他命、甲基苯丙胺和芬氟拉明进行顶空提取。Zr-UiO-66-PDC 在绿色条件下电合成,并通过各种分析进行表征,如 FT-IR、XRD、FE-SEM、EDS 和元素映射技术。然后,通过响应面法评估和优化了 NTD 效率的有效参数,如盐含量、pH 值、提取/解吸温度和时间。在 NaCl 含量为 27%、pH 值为 11.90 的情况下,在 70°C 下 50 分钟即可完成安非他命化合物的最佳提取。检测限和定量限因素分别确定为 0.06-0.09 和 0.5-0.8ngmL。此外,所采用的程序的精密度和准确度(日内和日间)以相对标准偏差(RSD)计算,范围为 8.0-9.0%和 6.8-9.8%。此外,在 4°C 下采样并储存 10 天后,提取分析物的回收率在 95.0-97.0%范围内。最后,将所提出的程序应用于实际尿液样品中安非他命化合物的分析。这些结果证明,所提出的 Zr-UiO-66-PDC@HS-NTD 技术与 GC-FID 结合,可用于痕量分析尿液样品中安非他命化合物的环保、快速响应、灵敏、高效的药物测试程序。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ac61/9372183/4eed60c241a7/41598_2022_17861_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验