Suppr超能文献

一种用N-羟基-N,N-二苯基苯甲脒修饰的新型碳糊电极用于环境样品中镉(II)的电化学测定

A Novel Carbon Paste Electrode Modified with N-Hydroxy-N,N-Diphenylbenzamidine for the Electrochemical Determination of Cadmium(II) in Environmental Samples.

作者信息

Tesfaye Endale, Singh Chandravanshi Bhagwan, Negash Negussie, Tessema Merid

机构信息

Department of Chemistry, College of Natural and Computational Sciences, Addis Ababa University, P. O. Box 1176, Addis Ababa, Ethiopia.

出版信息

J Anal Methods Chem. 2022 Sep 22;2022:3426575. doi: 10.1155/2022/3426575. eCollection 2022.

Abstract

The present study introduces a novel electrode for rapid, highly sensitive, and selective electrochemical sensor for cadmium(II) using 5% N-hydroxy-N,N-diphenylbenzamidine (HDPBA) modified carbon paste electrode (CPE) (HDPBA‒CPE). Surface characterizations and structural analysis of the proposed HDPBA‒CPE were performed using several analytical techniques. The voltammetric measurements of Cd(II) were conducted by cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). Several experimental conditions such as composition and pH of buffer solutions, HDPBA composition, accumulation potential and time, and other voltammetric conditions were optimized. Cd(II) was preconcentrated on the modified electrode surface for 270 s using Britton Robinson (B-R) buffer (0.1 M, pH 4) at -1.0 V versus Ag/AgCl, followed by electrochemical oxidation of the accumulated Cd(II) in the positive scan of SWASV after a quiet time of 10 s. Under optimized parameters, the proposed method showed a linear range of 0.3-100 nM Cd(II) with a detection limit of 0.032 nM. The fabricated HDPBA-modified carbon paste electrode exhibited excellent sensitivity, selectivity, stability, and reproducibility (with RSD of 3.8%). The developed HDPBA‒CPE was used for the quantification of Cd(II) in tobacco and environmental water samples, and it was found to be applicable for the determination of different types of real samples.

摘要

本研究介绍了一种新型电极,即使用5% N-羟基-N,N-二苯基苯甲脒(HDPBA)修饰的碳糊电极(CPE)(HDPBA-CPE)构建的用于镉(II)的快速、高灵敏度和选择性电化学传感器。采用多种分析技术对所提出的HDPBA-CPE进行了表面表征和结构分析。通过循环伏安法(CV)和方波阳极溶出伏安法(SWASV)对Cd(II)进行伏安测量。对缓冲溶液的组成和pH值、HDPBA组成、富集电位和时间以及其他伏安条件等几个实验条件进行了优化。使用Britton Robinson(B-R)缓冲液(0.1 M,pH 4)在相对于Ag/AgCl为-1.0 V的电位下将Cd(II)预富集在修饰电极表面270 s,然后在10 s的静止时间后,在SWASV的正向扫描中对积累的Cd(II)进行电化学氧化。在优化参数下,所提出的方法对Cd(II)的线性范围为0.3-100 nM,检测限为0.032 nM。制备的HDPBA修饰碳糊电极表现出优异的灵敏度、选择性、稳定性和重现性(相对标准偏差为3.8%)。所开发的HDPBA-CPE用于烟草和环境水样中Cd(II)的定量分析,结果表明它适用于不同类型实际样品的测定。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/58fb/9553701/79c734ff9a11/JAMC2022-3426575.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验