Briones Lee Jerome, Gomez James Paul, Leuenberger Edgar Felipe
Department of Ophthalmology, University of the East Ramon Magsaysay Memorial Medical Center Inc, Quezon City, Philippines.
Department of Ophthalmology, Asian Eye Institute, Makati City, Philippines.
Clin Ophthalmol. 2022 Oct 14;16:3437-3445. doi: 10.2147/OPTH.S376818. eCollection 2022.
This study aimed to determine if near visual acuity measurements using a Philippine peso bill are comparable to a standard Jaeger chart.
This is a cross-sectional study comparing the near visual acuity measurements of a Philippine peso bill and a Jaeger chart among sixty subjects.
LogMAR scores from the two methods were analyzed using Wilcoxon Mann-Whitney test. The relationship of the logMAR scores between these methods was determined using Spearman rank order correlation. The Bland-Altman plot was used to determine the comparability between quantitative measurements for near visual acuity using the standard Jaeger chart (reference) and the Philippine peso bill.
There were no significant differences in the proportion of Jaeger scores and mean logMAR equivalents between the two methods (p > 0.05). The scatter plot diagram shows a positive upward trend with a very strong and significant correlation between logMAR scores of Jaeger chart and Philippine peso bill methods (r = 0.9258, p < 0.0001). With a concordance correlation coefficient of 0.9505, there is a high agreement between these two measures. The Philippine peso bill overestimates the Jaeger chart visual acuity by 0.04 logMAR units. We suspect that the contrast between the background color and the serial numbers of the peso bill may have brought about this outcome.
The Philippine peso bill may be used as an alternative measuring tool for near visual acuity. However, there is a tendency to overestimate the scores obtained using the Philippine peso bill. Future studies are recommended to validate the results in a tele-ophthalmology setting.
本研究旨在确定使用菲律宾比索纸币测量近视力是否与标准耶格视力表相当。
这是一项横断面研究,比较了60名受试者使用菲律宾比索纸币和耶格视力表测量的近视力。
使用Wilcoxon Mann-Whitney检验分析两种方法的LogMAR得分。使用Spearman等级相关确定这些方法之间LogMAR得分的关系。使用Bland-Altman图确定使用标准耶格视力表(参考)和菲律宾比索纸币测量近视力的定量测量之间的可比性。
两种方法之间耶格视力得分比例和平均LogMAR等效值无显著差异(p>0.05)。散点图显示呈正上升趋势,耶格视力表和菲律宾比索纸币方法的LogMAR得分之间存在非常强且显著的相关性(r=0.9258,p<0.0001)。一致性相关系数为0.9505,这两种测量方法之间具有高度一致性。菲律宾比索纸币测量的视力比耶格视力表高估0.04个LogMAR单位。我们怀疑比索纸币背景颜色和序列号之间的对比度可能导致了这一结果。
菲律宾比索纸币可作为近视力的替代测量工具。然而,使用菲律宾比索纸币测量的得分有被高估的趋势。建议未来的研究在远程眼科环境中验证结果。