Arm positions employed during magnetic resonance imaging (MRI) can affect magnetic field distribution, which may result in variability in proton density fat fraction (PDFF) measurements. This study evaluated the effect of arm position on lumbar PDFF measured using chemical-shift-encoded MRI (CSE-MRI). Fifteen healthy volunteers from a single-center underwent lumbar CSE-MRI at two different arm positions (side and elevated) using a single 3T scanner. Scans were performed twice in each position. PDFFs of the L1-L5 vertebrae were independently measured by two readers and reader measurements were compared by calculating intraclass correlation coefficients (ICC). We compared PDFF measurements from two arm positions and from two consecutive scans using the Wilcoxon test and Bland-Altman analysis. Measurements from the two readers were in high agreement [ICC =0.999; 95% confidence interval (CI), 0.998-0.999]. No significant difference was observed between PDFFs from the first and second scans of all vertebrae for each reader (all P>0.05); however, PDFF for the elevated arm position was significantly higher than that for the side arm position (37.9-44.8% 37.0-43.8%; all P<0.05), except at the L2 level by reader 2. The mean differences in PDFF measurements from the first and second scans [0.1%; 95% limits of agreement (LoA), -1.8% to 1.9%] and from the side arm and elevated arm positions (0.8%; 95% LoA, -1.6% to 3.2%) were small. In conclusion, these preliminary data suggest that different arm positions during CSE-MRI can slightly affect lumbar PDFF; however, the mean absolute differences were very small.
磁共振成像(MRI)过程中采用的手臂位置会影响磁场分布,这可能导致质子密度脂肪分数(PDFF)测量结果出现差异。本研究评估了手臂位置对使用化学位移编码MRI(CSE-MRI)测量的腰椎PDFF的影响。来自单一中心的15名健康志愿者使用一台3T扫描仪,在两个不同的手臂位置(身体一侧和上举)接受了腰椎CSE-MRI检查。每个位置进行两次扫描。L1-L5椎体的PDFF由两名阅片者独立测量,并通过计算组内相关系数(ICC)比较阅片者的测量结果。我们使用Wilcoxon检验和Bland-Altman分析比较了两个手臂位置以及两次连续扫描的PDFF测量结果。两名阅片者的测量结果一致性很高[ICC =0.999;95%置信区间(CI),0.998 - 0.999]。每位阅片者对所有椎体的第一次和第二次扫描的PDFF之间均未观察到显著差异(所有P>0.05);然而,除阅片者2测量的L2水平外,上举手臂位置的PDFF显著高于身体一侧手臂位置的PDFF(37.9 - 44.8%对37.0 - 43.8%;所有P<0.05)。第一次和第二次扫描的PDFF测量结果的平均差异[0.1%;95%一致性界限(LoA),-1.8%至1.9%]以及身体一侧手臂位置和上举手臂位置的平均差异(0.8%;95% LoA,-1.6%至3.2%)都很小。总之,这些初步数据表明,CSE-MRI过程中不同的手臂位置会轻微影响腰椎PDFF;然而,平均绝对差异非常小。