Suppr超能文献

从动态 CT 成像中全自动提取膝关节运动学;100 名健康志愿者的正常胫股和髌股运动学。

Fully automatic extraction of knee kinematics from dynamic CT imaging; normative tibiofemoral and patellofemoral kinematics of 100 healthy volunteers.

机构信息

Orthopaedic Research Laboratory, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, the Netherlands.

Department of Orthopaedics, Radboud University Medical Center, Nijmegen, the Netherlands.

出版信息

Knee. 2023 Mar;41:9-17. doi: 10.1016/j.knee.2022.12.011. Epub 2023 Jan 4.

Abstract

BACKGROUND

Accurate assessment of knee kinematics is important in the diagnosis and quantification of knee disorders and to determine the effect of orthopaedic interventions. Despite previous studies showing the usefulness of dynamic imaging and providing valuable insights in knee kinematics, dynamic imaging is not widely used in clinics due to a variety of causes. In this study normative knee kinematics of 100 healthy subjects is established using a fully automatic workflow feasible for use in the clinic.

METHODS

One-hundred volunteers were recruited and a dynamic CT scan was made during a flexion extension movement. Image data was automatically segmented and dynamic and static images were superimposed using image registration. Coordinate systems for the femur, patella and tibia were automatically calculated as well as their dynamic position and orientation.

RESULTS

Dynamic CT scans weremade withan effective radiation dose of 0.08 mSv. The median tibial internal rotation was 4° and valgus rotation is 5° at full flexion. Femoral rollback of the lateral condyle was 7 mm versus 2 mm of the medial condyle. The median patella flexion reached 65% of tibiofemoral flexion and the median tilt and rotation were 5° and 0° at full flexion, respectively. The median mediolateral translation of the patella was 3 mm (medially) in the first 30° of flexion.

CONCLUSION

The current study presents TF and PF kinematic data of 97 healthy individuals, providing a unique dataset of normative knee kinematics. The short scanning time, simple motion and, automatic analysis make the methods presented suitable for daily clinical practice.

摘要

背景

准确评估膝关节运动学对于膝关节疾病的诊断和量化以及确定矫形干预措施的效果非常重要。尽管之前的研究表明动态成像具有实用性,并为膝关节运动学提供了有价值的见解,但由于各种原因,动态成像并未在临床中广泛应用。在本研究中,使用完全自动化的工作流程建立了 100 名健康受试者的膝关节运动学的正常参考值,该流程可在临床中使用。

方法

招募了 100 名志愿者,并在膝关节屈伸运动过程中进行了动态 CT 扫描。使用图像配准自动对图像数据进行分割,并将动态和静态图像进行叠加。自动计算股骨、髌骨和胫骨的坐标系及其动态位置和方向。

结果

动态 CT 扫描的有效辐射剂量为 0.08mSv。完全屈曲时,胫骨内旋的中位数为 4°,外翻旋转为 5°。外侧髁的股骨后滚为 7mm,而内侧髁为 2mm。髌骨的最大屈曲达到胫股关节屈曲的 65%,完全屈曲时髌骨的倾斜和旋转中位数分别为 5°和 0°。髌骨的内外侧平移中位数在屈曲的前 30°为 3mm(内侧)。

结论

本研究提出了 97 名健康个体的 TF 和 PF 运动学数据,提供了膝关节运动学正常参考值的独特数据集。短的扫描时间、简单的运动和自动分析使所提出的方法适用于日常临床实践。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验