Suppr超能文献

用于代谢组学的液相色谱-质谱代谢物库:使用评分方法评估色谱柱适用性。

Liquid chromatography-mass spectrometry metabolite library for metabolomics: Evaluating column suitability using a scoring approach.

作者信息

Diamantidou Dimitra, Sampsonidis Ioannis, Liapikos Theodoros, Gika Helen, Theodoridis Georgios

机构信息

Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 541 24, Thessaloniki, Greece; Biomic_AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, Thessaloniki, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001; FoodOmicsGR Research Infrastructure, AUTh node, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, Thessaloniki, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001.

FoodOmicsGR Research Infrastructure, AUTh node, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center, B1.4, Thessaloniki, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, GR 57001; Laboratory of Chemical Biology, Department of Nutritional Sciences and Dietetics, International Hellenic University, Thessaloniki, GR, 574 00, Greece.

出版信息

J Chromatogr A. 2023 Feb 8;1690:463779. doi: 10.1016/j.chroma.2023.463779. Epub 2023 Jan 11.

Abstract

Untargeted metabolomic studies require an extensive set of analyte (metabolic) information to be obtained from each analyzed sample. Thus, highly selective, and efficient analytical methodologies together with reversed-phase (RP) or hydrophilic interaction liquid chromatography (HILIC) are usually applied in these approaches. Here, we present a performance comparison of five different chromatographic columns (C18, C8, RP Amide, zicHILIC, OH5 HILIC phases) to evaluate their sufficiency of analysis for a large analyte library, consisting of 817 authentic standards. By taking into account experimental chromatographic parameters (i.e. retention time, peak tailing and asymmetry, FWHM, signal-to-noise ratio and peak area and intensity), the proposed column scoring approach provides a simple criterion that may assist analysis in the select of a stationary phase for those metabolites of interest. RPLC methods offered better results regarding metabolic library coverage, while the zicHILIC stationary phase delivered a bigger number of properly eluted compounds. This study demonstrates the importance of choosing the most suitable configuration for the analysis of different metabolic classes.

摘要

非靶向代谢组学研究需要从每个分析样本中获取大量的分析物(代谢物)信息。因此,这些方法通常采用高选择性、高效的分析方法以及反相(RP)或亲水作用液相色谱(HILIC)。在此,我们对五种不同的色谱柱(C18、C8、RP酰胺、zicHILIC、OH5 HILIC固定相)进行了性能比较,以评估它们对由817种 authentic标准品组成的大型分析物库的分析充分性。通过考虑实验色谱参数(即保留时间、峰拖尾和不对称性、半高宽、信噪比以及峰面积和强度),所提出的柱评分方法提供了一个简单的标准,可有助于为感兴趣的那些代谢物选择固定相时的分析。反相液相色谱方法在代谢物库覆盖方面提供了更好的结果,而zicHILIC固定相洗脱的化合物数量更多。本研究证明了为不同代谢类别分析选择最合适配置的重要性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验