Suppr超能文献

编辑精选 - 在意大利分支型腔内移植物注册研究(INBREED)中,使用新型即用型预装分支内支架治疗复杂主动脉病变的早期结果。

Editor's Choice - Early Outcomes of a Novel Off the Shelf Preloaded Inner Branch Endograft for the Treatment of Complex Aortic Pathologies in the ItaliaN Branched Registry of E-nside EnDograft (INBREED).

机构信息

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

出版信息

Eur J Vasc Endovasc Surg. 2023 Jun;65(6):811-817. doi: 10.1016/j.ejvs.2023.02.076. Epub 2023 Mar 3.

Abstract

OBJECTIVE

The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies.

METHODS

Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days.

RESULTS

In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention.

CONCLUSION

In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.

摘要

目的

本研究旨在探讨一种新型即弃式预装分支胸腹主动脉覆膜内支架(E-nside)治疗主动脉病变的早期结果。

方法

对接受 E-nside 覆膜内支架治疗的患者进行了一项由医生发起的全国多中心注册研究的数据,前瞻性地进行了收集和分析。在专门的电子数据捕获系统中记录了术前临床和解剖特征、手术数据以及早期(90 天)结果。主要终点是技术成功。次要终点是 90 天内的早期死亡率、手术指标、靶血管通畅率、内漏率和主要不良事件(MAE)。

结果

共纳入来自意大利 31 个中心的 116 名患者。患者的平均年龄为 73±8 岁,76 名(65.5%)为男性。主动脉病变包括退行性动脉瘤 98 例(84.5%)、夹层后动脉瘤 5 例(4.3%)、假性动脉瘤 6 例(5.2%)、穿透性主动脉溃疡或壁内血肿 4 例(3.4%)和亚急性夹层 3 例(2.6%)。平均直径为 66±17mm;动脉瘤范围在 Crawford I-III 期 55 例(50.4%),IV 期 21 例(19.2%),肾周 29 例(26.7%),肾下 4 例(3.7%)。手术设置为紧急情况的有 25 例(21.5%)。中位手术时间为 240 分钟(四分位距 [IQR] 195,303),中位造影剂用量为 175ml(IQR 120,235)。内支架的技术成功率为 98.2%,90 天死亡率为 5.2%(n=6;择期修复为 2.1%,急诊修复为 16%)。90 天的累积 MAE 率为 24.1%(n=28)。90 天时,有 10 例(2.3%)发生靶血管相关事件(9 例闭塞和 1 例 1C 型内漏),1 例 1A 型内漏需要再次介入治疗。

结论

在这项真实世界、非赞助的注册研究中,E-nside 覆膜内支架用于治疗多种主动脉病变,包括紧急情况和不同解剖结构。结果显示了出色的技术植入安全性和疗效,以及早期结果。需要更长时间的随访来更好地定义这种新型内支架的临床作用。