Suppr超能文献

二维和三维系统分析全髋关节置换术中短柄锥形楔形股骨柄的应力屏蔽与最佳股骨管接触区域的关系

Relationship between Stress Shielding and Optimal Femoral Canal Contact Regions for Short, Tapered-Wedge Stem Analyzed by 2D and 3D Systems in Total Hip Arthroplasty.

作者信息

Maeda Takashi, Nakano Masaki, Nakamura Yukio, Momose Takashige, Sobajima Atsushi, Takahashi Jun, Nakata Katsuya, Nawata Masashi

机构信息

Department of Orthopaedic Surgery, Marunouchi Hospital, Matsumoto 390-8601, Japan.

Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto 390-8621, Japan.

出版信息

J Clin Med. 2023 Apr 26;12(9):3138. doi: 10.3390/jcm12093138.

Abstract

Although tapered-wedge short stem has been widely employed with its availability for minimally invasive surgeries in total hip arthroplasty (THA), post-operative stress shielding matter remains unresolved in cementless procedures. This study aimed to clarify the most optimal femoral canal contact regions of the stem design taking stress shielding incidence into consideration. This investigation included 60 joints from 60 patients (mean age at operation: 65.9 years), of which follow-up duration after primary THA had been more than 2 years. Frequencies of spot welds, subsidence, and stress shielding were examined 2 years after surgery. The most suitable femoral canal contact regions were evaluated by plain radiograph (2D) and 3D-computed tomography analyses according to Nakata's division for fitting manners. Spot welds were observed in 38 cases (63.3%), and no subsidence case was seen. Respective number of stress shielding cases, based on Engh's classification, categorized as degree 0, 1, and 2, were 2 (3.3%), 31 (51.7%), and 27 (45.0%), while no cases for degree 3 or 4 were found. When assessed by 3D fitting analysis, 27 cases of stress shielding degree 2 were constituted by 13/42 cases of mediolateral (ML) fit, 2/4 cases of flare fit, and 12/14 cases of multi point fit. In 42 cases of ML fitting, stem contact rate of the most proximedial region in stress shielding degree 0 and 1 was significantly higher compared to stress shielding degree 2 cases. Meanwhile, the rates of distal regions were significantly lower or absent in stress shielding degree 0 and 1 cases. The initial fixation of this stem design was very good in our cohort regardless of fitting manners. This study successfully revealed that ML fitting with femoral component, especially the most proximedial calcar site restricted fitting, would be optimal for reducing stress shielding occurrence in cementless short, tapered-wedge stem THA. Thus, the ideal stem contact region should be considered during THA procedures in light of the reduction of stress shielding development.

摘要

尽管锥形楔形短柄因其可用于全髋关节置换术(THA)的微创手术而被广泛应用,但在非骨水泥手术中,术后应力遮挡问题仍未得到解决。本研究旨在考虑应力遮挡发生率,阐明柄设计的最佳股骨髓腔接触区域。本调查纳入了60例患者的60个关节(手术时平均年龄:65.9岁),其中初次THA术后随访时间超过2年。术后2年检查点焊、下沉和应力遮挡的发生率。根据中田的拟合方式划分,通过X线平片(2D)和三维计算机断层扫描分析评估最合适的股骨髓腔接触区域。38例(63.3%)观察到点焊,未发现下沉病例。根据恩格分类,应力遮挡病例中,0级、1级和2级的病例数分别为2例(3.3%)、31例(51.7%)和27例(45.0%),未发现3级或4级病例。通过三维拟合分析评估时,27例应力遮挡2级病例由13/42例内外侧(ML)拟合、2/4例扩口拟合和12/14例多点拟合构成。在42例ML拟合中,应力遮挡0级和1级时最近端区域的柄接触率显著高于应力遮挡2级病例。同时,应力遮挡0级和1级病例中远端区域的接触率显著较低或无接触。在我们的队列中,无论拟合方式如何,这种柄设计的初始固定都非常好。本研究成功揭示,股骨部件的ML拟合,尤其是最近端的股骨距部位受限拟合,对于减少非骨水泥短柄锥形楔形柄THA中的应力遮挡发生是最佳的。因此,在THA手术过程中,应考虑理想的柄接触区域以减少应力遮挡的发生。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b184/10179674/ded710b1cfdb/jcm-12-03138-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验