Suppr超能文献

一项关于圆窗及其毗邻解剖结构以指导人工耳蜗电极植入的研究。

A Study of Round Window and its Adjacent Anatomy to Guide the Cochlear Implant Electrode Insertion.

作者信息

Kataria Tanmaya, Sharma Shitanshu, Lakhawat Rajendra Singh, Grover Mohnish, Sharma Shivam, Kanodia Anupam, Agarwal Srishti, Samdani Sunil

机构信息

Department of Otorhinolaryngology, SMS Medical college, Jaipur, Rajasthan India.

Department of Otorhinolaryngology, RVRS Government Medical College, Bhilwara, Rajasthan India.

出版信息

Indian J Otolaryngol Head Neck Surg. 2023 Apr;75(Suppl 1):163-169. doi: 10.1007/s12070-022-03288-7. Epub 2022 Dec 10.

Abstract

INTRODUCTION

Residual hearing preservation has gained attention now which has brought round window membrane into the light, as a port for cochlear implantation. Atraumatic insertion of electrodes can be achieved by study of anatomical variations of round window and its forms which can guide the surgeon.

OBJECTIVE

This study was undertaken to examine the anatomical variations of round window and its adjacent structures and their impact on surgical approach during cochlear implantation.

METHODS

A series of 40 adult human temporal bones underwent high-resolution CT scanning and were further dissected for microscopic study of the round window.

RESULTS

The antero posterior dimensions of RW ranged from 1.22 to 2.51 mm on radiology and on dissection 1.76 mm +/- 0.3 mm. Shape of round window in 72.5% of bones was oval, and in 27.5% bones it was round shaped. As per Saint Thomas hospital classification for Round window visualization we found 82.5% bones had type I RW visualization and 17.5% had type IIa RW visualization. Area of crista fenestra on dissection was ranging from 0.41 to 0.69 mm.

CONCLUSION

Residual hearing preservation has become a new motto for surgeons. Therefore thorough anatomic knowledge of round window is must for careful insertion, as round window is closely related to the sensitive inner ear structures.

摘要

引言

如今,残余听力保留受到关注,这使得圆窗膜作为人工耳蜗植入的一个端口进入人们的视野。通过研究圆窗的解剖变异及其形态,可以实现电极的无创插入,这能够为外科医生提供指导。

目的

本研究旨在检查圆窗及其相邻结构的解剖变异,以及它们对人工耳蜗植入手术入路的影响。

方法

对40例成人颞骨进行了高分辨率CT扫描,并进一步解剖以对圆窗进行显微镜研究。

结果

在影像学上,圆窗的前后径范围为1.22至2.51毫米,解剖测量为1.76毫米±0.3毫米。72.5%的颞骨中圆窗形状为椭圆形,27.5%为圆形。根据圣托马斯医院对圆窗可视化的分类,我们发现82.5%的颞骨具有I型圆窗可视化,17.5%具有IIa型圆窗可视化。解剖时窗嵴的面积范围为0.41至0.69平方毫米。

结论

残余听力保留已成为外科医生的新座右铭。因此,由于圆窗与敏感的内耳结构密切相关,对于仔细插入电极而言,全面了解圆窗的解剖知识是必不可少的。

相似文献

1
A Study of Round Window and its Adjacent Anatomy to Guide the Cochlear Implant Electrode Insertion.
Indian J Otolaryngol Head Neck Surg. 2023 Apr;75(Suppl 1):163-169. doi: 10.1007/s12070-022-03288-7. Epub 2022 Dec 10.
2
Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion.
Otol Neurotol. 2016 Jan;37(1):52-6. doi: 10.1097/MAO.0000000000000921.
3
The Crista Fenestra and Its Impact on the Surgical Approach to the Scala Tympani during Cochlear Implantation.
Audiol Neurootol. 2017;22(1):50-55. doi: 10.1159/000471840. Epub 2017 Jun 23.
4
Applied anatomy of round window and adjacent structures of tympanum related to cochlear implantation.
Braz J Otorhinolaryngol. 2019 Jul-Aug;85(4):435-446. doi: 10.1016/j.bjorl.2018.03.009. Epub 2018 Apr 19.
5
Surgical anatomy of the round window-Implications for cochlear implantation.
Clin Otolaryngol. 2018 Apr;43(2):417-424. doi: 10.1111/coa.13048. Epub 2018 Jan 3.
6
Cochlear implant electrode insertion: the round window revisited.
Laryngoscope. 2007 Aug;117(8):1397-402. doi: 10.1097/MLG.0b013e318064e891.
10
Does cochleostomy location influence electrode trajectory and intracochlear trauma?
Laryngoscope. 2015 Apr;125(4):966-71. doi: 10.1002/lary.24986. Epub 2014 Oct 27.

引用本文的文献

1
Evaluating round window niche visibility in cochlear implantation: anatomical insights and electrode insertion strategies.
Eur Arch Otorhinolaryngol. 2025 Jun;282(6):2927-2937. doi: 10.1007/s00405-024-09162-2. Epub 2025 Jan 3.
2
Cochlear Apex Triangulation Utilizing Ct Measures And Middle Ear Landmarks.
Otol Neurotol Open. 2024 Aug 23;4(3):e060. doi: 10.1097/ONO.0000000000000060. eCollection 2024 Sep.

本文引用的文献

2
Applied anatomy of round window and adjacent structures of tympanum related to cochlear implantation.
Braz J Otorhinolaryngol. 2019 Jul-Aug;85(4):435-446. doi: 10.1016/j.bjorl.2018.03.009. Epub 2018 Apr 19.
3
Surgical anatomy of the round window-Implications for cochlear implantation.
Clin Otolaryngol. 2018 Apr;43(2):417-424. doi: 10.1111/coa.13048. Epub 2018 Jan 3.
4
The Crista Fenestra and Its Impact on the Surgical Approach to the Scala Tympani during Cochlear Implantation.
Audiol Neurootol. 2017;22(1):50-55. doi: 10.1159/000471840. Epub 2017 Jun 23.
5
Is the human round window really round? An anatomic study with surgical implications.
Otol Neurotol. 2014 Sep;35(8):1354-60. doi: 10.1097/MAO.0000000000000332.
6
Surgical anatomy of round window and its implications for cochlear implantation.
Clin Anat. 2014 Apr;27(3):331-6. doi: 10.1002/ca.22339. Epub 2013 Dec 19.
7
Round window versus cochleostomy technique in cochlear implantation: histologic findings.
Otol Neurotol. 2012 Sep;33(7):1181-7. doi: 10.1097/MAO.0b013e318263d56d.
8
[Applied anatomy of facial recess and posterior tympanum related to cochlear implantation].
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2012 May;26(10):445-8.
9
Evaluation of round window accessibility to cochlear implant insertion.
Eur Arch Otorhinolaryngol. 2013 Mar;270(4):1237-42. doi: 10.1007/s00405-012-2106-4. Epub 2012 Jul 18.
10
Cochlear implant electrode insertion: the round window revisited.
Laryngoscope. 2007 Aug;117(8):1397-402. doi: 10.1097/MLG.0b013e318064e891.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验