使用铜-ATSM PET/MRI测量肾血流量的可行性:一项PET和MRI定量研究。

Feasibility of Renal Blood Flow Measurement Using Cu-ATSM PET/MRI: A Quantitative PET and MRI Study.

作者信息

Nishikawa Yudai, Takahashi Naoki, Nishikawa Sho, Shimamoto Yuki, Nishimori Kazuhisa, Kobayashi Mamiko, Kimura Hideki, Tsujikawa Tetsuya, Kasuno Kenji, Mori Tetsuya, Kiyono Yasushi, Okazawa Hidehiko, Iwano Masayuki

机构信息

Department of Nephrology, Faculty of Medical Sciences, University of Fukui, Fukui 910-1193, Japan.

Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan.

出版信息

Diagnostics (Basel). 2023 May 10;13(10):1685. doi: 10.3390/diagnostics13101685.

Abstract

This study aimed to evaluate the renal blood flow (RBF) in patients with chronic kidney disease (CKD) using Cu(II)-diacetyl-bis(4-methylthiosemicarbazonate) (Cu-ATSM) for positron emission tomography (PET)/magnetic resonance imaging (MRI). We included five healthy controls (HCs) and ten patients with CKD. The estimated glomerular filtration rate (eGFR) was calculated from the serum creatinine (cr) and cystatin C (cys) levels. The estimated RBF (eRBF) was calculated using the eGFR, hematocrit, and filtration fraction. A single dose of Cu-ATSM (300-400 MBq) was administered for RBF evaluation, and a 40 min dynamic PET scan was performed with simultaneous arterial spin labeling (ASL) imaging. PET-RBF images were obtained from the dynamic PET images at 3 min after injection using the image-derived input function method. The mean eRBF values calculated from various eGFR values differed significantly between the patients and HCs; both groups also differed significantly in terms of the RBF values (mL/min/100 g) measured using PET (151 ± 20 vs. 124 ± 22, < 0.05) and ASL-MRI (172 ± 38 vs. 125 ± 30, < 0.001). The ASL-MRI-RBF was positively correlated with the eRBFcr-cys (r = 0.858, < 0.001). The PET-RBF was positively correlated with the eRBFcr-cys (r = 0.893, < 0.001). The ASL-RBF was positively correlated with the PET-RBF (r = 0.849, < 0.001). Cu-ATSM PET/MRI demonstrated the reliability of PET-RBF and ASL-RBF by comparing them with eRBF. This is the first study to demonstrate that Cu-ATSM-PET is useful for assessing the RBF and is well correlated with ASL-MRI.

摘要

本研究旨在使用铜(II)-双乙酰双(4-甲基硫代半卡巴腙)(Cu-ATSM)进行正电子发射断层扫描(PET)/磁共振成像(MRI),以评估慢性肾脏病(CKD)患者的肾血流量(RBF)。我们纳入了5名健康对照者(HCs)和10名CKD患者。根据血清肌酐(cr)和胱抑素C(cys)水平计算估计肾小球滤过率(eGFR)。使用eGFR、血细胞比容和滤过分数计算估计肾血流量(eRBF)。给予单剂量的Cu-ATSM(300 - 400 MBq)用于RBF评估,并进行40分钟的动态PET扫描,同时进行动脉自旋标记(ASL)成像。使用图像衍生输入函数法从注射后3分钟的动态PET图像中获取PET-RBF图像。根据不同eGFR值计算的平均eRBF值在患者和HCs之间存在显著差异;两组在使用PET测量的RBF值(mL/min/100 g)(151±20 vs. 124±22,P<0.05)和ASL-MRI测量的RBF值(172±38 vs. 125±30,P<0.001)方面也存在显著差异。ASL-MRI-RBF与eRBFcr-cys呈正相关(r = 0.858,P<0.001)。PET-RBF与eRBFcr-cys呈正相关(r = 0.893,P<0.001)。ASL-RBF与PET-RBF呈正相关(r = 0.849,P<0.001)。通过将PET-RBF和ASL-RBF与eRBF进行比较,Cu-ATSM PET/MRI证明了PET-RBF和ASL-RBF的可靠性。这是第一项证明Cu-ATSM-PET可用于评估RBF且与ASL-MRI具有良好相关性的研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d4bf/10216934/d817efddbb51/diagnostics-13-01685-g001.jpg