Suppr超能文献

职业高尔夫球手在正式比赛中的运动强度和活动能量消耗。

Exercise Intensity and Activity Energy Expenditure of Professional Golf Players in Official Competitive Setting.

机构信息

Department of Interventional Cardiology, Heart Center, Policlinico di Monza, Monza, Italy.

Clinical and Sport Nutrition, Bianalisi, Monza, Italy.

出版信息

Sports Health. 2024 May-Jun;16(3):481-486. doi: 10.1177/19417381231175149. Epub 2023 Jun 6.

Abstract

BACKGROUND

Research regarding the physical needs of professional golf players is lacking. With advances in wearable technology, it has become easier to analyze physiological responses such as heart rate (HR) to determine activity energy expenditure (AEE). The purpose of the study was to evaluate exercise intensity (EI) and AEE during 4 consecutive tournament's golf rounds using a popular wrist-based HR monitoring.

HYPOTHESIS

Wearable systems for HR monitoring can be used to provide an accurate estimate of energy expenditure.

STUDY DESIGN

Cross-sectional study.

LEVEL OF EVIDENCE

Level 3.

METHODS

A total of 20 male professional golfers participated in the study. Each player was monitored during an official tournament consisting of 4 rounds of 18 holes. EI and AEE were determined using HR wrist monitoring (Whoop Strap 2.0). We calculated the percentage of HR (%HR) and the percentage of HR (%HR) and the AEE in kcal/min using Keytel's formula.

RESULTS

The calculated mean %HR and %HR for the study population were 56.4% ± 1.8% and 40.5% ± 2.6%, respectively. Considering American College of Sports Medicine guidelines, these average percentages correspond to a moderate EI. The average caloric expenditure was 5.4 ± 0.4 kcal/min and 1555.8 ± 157.8 kcal per round considering an average golf round duration of 288.3 ± 19.5 minutes.

CONCLUSION

A professional player's golf round is moderate physical activity. The AEE of this activity was equal to 5.4 cal/min, which is moderate energy consumption.

CLINICAL RELEVANCE

These data could help golf coaches and conditioning coaches to have a better understanding of the load placed on golfers during tournaments.

摘要

背景

目前针对职业高尔夫球员身体需求的研究较为缺乏。随着可穿戴技术的进步,分析心率(HR)等生理反应来确定活动能量消耗(AEE)变得更加容易。本研究的目的是使用流行的腕部 HR 监测仪评估 4 场连续高尔夫球比赛中的运动强度(EI)和 AEE。

假设

用于 HR 监测的可穿戴系统可用于提供能量消耗的准确估计。

研究设计

横断面研究。

证据等级

3 级。

方法

共有 20 名男性职业高尔夫球手参与了这项研究。每位球员在由 4 轮 18 洞组成的正式比赛中接受监测。使用 HR 腕部监测仪(Whoop Strap 2.0)确定 EI 和 AEE。我们使用 Keytel 公式计算 HR 百分比(%HR)和 AEE 百分比(%HR)和以 kcal/min 为单位的 AEE。

结果

研究人群的计算平均%HR 和%HR 分别为 56.4%±1.8%和 40.5%±2.6%。考虑到美国运动医学学院的指南,这些平均百分比对应于中等 EI。考虑到平均高尔夫回合持续时间为 288.3±19.5 分钟,平均热量消耗为 5.4±0.4 kcal/min 和 1555.8±157.8 kcal/轮。

结论

职业高尔夫球手的一轮高尔夫球是适度的体力活动。该活动的 AEE 等于 5.4 cal/min,属于中等能量消耗。

临床相关性

这些数据可以帮助高尔夫教练和体能教练更好地了解高尔夫球手在比赛中承受的负荷。

相似文献

3
Energy expenditure and sex differences of golf playing.高尔夫运动的能量消耗与性别差异。
J Sports Sci. 2013;31(10):1045-53. doi: 10.1080/02640414.2013.764465. Epub 2013 Jan 30.
4
Development of a simulated round of golf.发展一轮模拟高尔夫球。
Int J Sports Physiol Perform. 2009 Dec;4(4):506-16. doi: 10.1123/ijspp.4.4.506.
7
Intensity of official Futsal matches.五人制足球官方比赛的强度。
J Strength Cond Res. 2011 Sep;25(9):2482-7. doi: 10.1519/JSC.0b013e3181fb4574.

本文引用的文献

7
Accuracy of Wrist-Worn Heart Rate Monitors.腕戴式心率监测仪的准确性。
JAMA Cardiol. 2017 Jan 1;2(1):104-106. doi: 10.1001/jamacardio.2016.3340.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验