Suppr超能文献

磁共振声电计算断层成像(MAE-CT)中的迭代重建算法,用于改善图像质量。

Iterative Reconstruction Algorithms in Magneto-Acousto-Electrical Computed Tomography (MAE-CT) for Image Quality Improvement.

出版信息

IEEE Trans Biomed Eng. 2024 Feb;71(2):669-678. doi: 10.1109/TBME.2023.3314617. Epub 2024 Jan 19.

Abstract

Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.

摘要

磁声电计算层析成像(MAE-CT)是一种新发展的旋转磁声电层析成像(MAET)方法,它可以高空间分辨率对组织的电导率参数进行成像。由于 MAE-CT 的成像模式与 CT 类似,因此 CT 的重建算法可能适用于 MAE-CT。先前的研究已经证明,滤波反投影(FBP)算法,作为最常见的 CT 重建算法之一,可用于 MAE-CT 重建。然而,FBP 存在一些固有缺点,例如对噪声敏感和视角非均匀分布。在这项研究中,我们在 MAE-CT 重建中引入了迭代重建(IR)方法,并比较了它与 FBP 的性能。进行了数值模拟、体模和体外实验,并使用了几种 IR 算法(ART、SART、SIRT)进行重建。结果表明,在模拟中数据无噪声时,FBP 和 IR 重建的图像相似。随着噪声水平的增加,SART 和 SIRT 重建的图像对噪声的鲁棒性优于 FBP。在体模实验中,SART 和 SIRT 算法去除了 FBP 产生的噪声和一些条纹伪影。总之,CT 中使用的 IR 方法适用于 MAE-CT,并且其性能优于 FBP,这表明 CT 算法的最新成果也可用于未来的 MAE-CT 重建。

相似文献

1
Iterative Reconstruction Algorithms in Magneto-Acousto-Electrical Computed Tomography (MAE-CT) for Image Quality Improvement.
IEEE Trans Biomed Eng. 2024 Feb;71(2):669-678. doi: 10.1109/TBME.2023.3314617. Epub 2024 Jan 19.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验